New Study Maps Voltage and Temperature-Rise Matching Path for power battery Replacement in New Energy Buses

A comprehensive engineering study on power battery replacement in new energy buses has identified why a new, higher-voltage power battery can trigger failures in aged electronic control systems, particularly batch burnout of insulated gate bipolar transistors, and has demonstrated a practical retrofit path that avoids replacing the entire controller. The research systematically compares the electrical characteristics of a new power battery with those of motor controllers that have operated for more than eight years, locates the root cause through bench testing, proposes targeted engineering improvements and verifies the results through real-vehicle operation. The central finding is that insufficient heat dissipation caused by aging is a key factor constraining voltage parameter matching between new and old components, and that improving controller heat dissipation while reducing heat generation can effectively solve voltage and temperature-rise matching problems. The work provides technical support and an engineering reference for voltage parameter matching, temperature-rise control, fault troubleshooting and efficiency improvement during power battery replacement in new energy buses.

The study arrives at a critical moment for the new energy bus sector. Under decarbonization strategies and new urbanization, new energy buses have become a core carrier for the green transformation of public transportation, and the power battery is the core power source and the lifeline of stable vehicle operation. The first batch of new energy buses is now entering the power battery decay period, with problems such as capacity decline, efficiency reduction and even safety hazards becoming a bottleneck for high-quality industrial development. Policies have been introduced to support power battery replacement and provide fixed subsidies. In practice, however, replacement can easily cause faults because new power battery characteristics do not match those of aged electronic control systems. In one fleet case, the rated voltage was raised from 460 V direct current to 600 V direct current, after which batch burnout of controller IGBTs occurred. Systematic research in the industry has been scarce, so the case-based study focuses on voltage parameter matching, analyzes characteristic differences and fault causes, and proposes and verifies improvement strategies for standardized implementation of power battery replacement.

1. Background: power battery Replacement Enters a Critical Matching Phase

The transition toward low-emission public transport has made the power battery one of the most closely watched components in the bus industry. A new energy bus depends on its power battery not only for range but also for stable power delivery across duty cycles that include frequent starts, stops, grade climbing and passenger loading changes. As early fleets age, the power battery becomes the first major system to show measurable decline. Capacity loss and efficiency reduction are the most visible symptoms, but the more complex challenge is the interaction between a new power battery and the aging electronic control system that was originally designed and calibrated around an older power battery pack.

The study notes that power battery replacement is often treated as a mechanical and electrical interface task: remove the old pack, install the new pack and update basic parameters. That approach can overlook the fact that a new power battery has different internal resistance, voltage stability and current delivery characteristics. It can also overlook the fact that an aged controller is no longer the same controller it was when new. Voltage sampling chains drift, power devices degrade, thermal interfaces dry out and control algorithms may lack coordinated voltage-current protection. When a new power battery with lower internal resistance and higher voltage stability is connected to such a controller, the system may appear to operate normally at first while accumulating thermal and electrical stress that eventually produces failure.

The fleet case examined in the study illustrates the risk. The vehicles had operated for more than eight years, and their original power battery packs had reached a state of health of about 75 percent. The replacement power battery raised the rated voltage from 460 V to 600 V. The new voltage remained within the controller’s wide voltage design range of 350 V to 720 V, yet batch IGBT burnout occurred. That contradiction is central to the study: a parameter can be inside the declared hardware range and still create an unacceptable thermal burden when the controller is aged and the power battery is new. The research therefore treats power battery replacement as a system matching problem involving voltage, current, thermal behavior and control precision.

2. Voltage Characteristics of the New power battery and the Aged power battery

The study compares key voltage characteristics of a new lithium iron phosphate power battery with those of an old power battery that has operated for eight years and reached a state of health of 75 percent. The data show significant differences in internal resistance, pulse voltage drop, open-circuit voltage and operating voltage range. These differences matter because they determine how the power battery behaves under load transients and how much precision the controller must have to regulate current and protect power devices.

Parameter New power battery Aged power battery
Cell internal resistance 0.8–1.2 mΩ 1.5–2.5 mΩ
Module internal resistance 12–18 mΩ 25–40 mΩ
10C pulse voltage drop 0.15–0.25 V 0.35–0.60 V
Open-circuit voltage 3.25–3.35 V 3.20–3.30 V after decay
Operating voltage range 2.50–3.65 V 2.80–3.55 V, limited

The new power battery has the core advantages of low internal resistance and high voltage stability. Its voltage characteristics can be summarized in two points. First, voltage fluctuation under load changes is small and response is fast, which places higher requirements on the voltage sampling rate of the electronic control system. Second, polarization voltage is low, so at the same terminal voltage the constant-power output current is larger during high-current discharge. This requires higher current control precision from the controller. If control precision is insufficient, current overload can occur even though the power battery itself is performing within its normal capability.

The aged power battery shows the opposite profile. Higher internal resistance produces larger pulse voltage drop, and the limited operating voltage range reduces the margin available to the controller. When such a power battery is replaced by a new power battery, the controller must cope with a source that can deliver current more readily and maintain voltage more firmly. For an aged controller, that combination can expose weaknesses that were previously masked by the degraded power battery. The new power battery is not inherently incompatible, but it changes the electrical environment in which the aged controller operates.

The study emphasizes that power battery matching cannot rely only on nominal voltage. The new power battery’s low internal resistance means that the same terminal voltage can support a larger current under constant-power demand. The aged controller’s current regulation loop, voltage sampling chain and thermal design must be evaluated together. If the controller was calibrated around an older power battery with higher internal resistance, the arrival of a new power battery can shift the operating point toward higher current and higher losses. That shift is especially important during starting and peak-load conditions, when the power battery can supply high current and the controller’s power devices are already near their thermal limits.

3. Aging Electronic Control: Sampling Drift, Power Device Degradation and Control Limits

Electronic control systems that have operated for more than eight years are affected by device aging and environmental erosion, and their electrical performance and control precision deteriorate significantly. The study identifies three core aging characteristics: voltage sampling chain drift, power device degradation and incomplete control algorithms or protection logic. Each characteristic influences how the controller interacts with a new power battery.

  • Voltage sampling chain drift. Aging of the high-voltage divider resistor network causes resistance drift of ±2 percent to ±5 percent. In a 600 V system, total voltage sampling error can reach ±10 V to ±20 V. Zero drift of the operational amplifier causes cell voltage detection error to increase from an initial ±5 mV to ±15 mV. Reference voltage drift in the analog-to-digital converter chip increases measurement error, and the problem is more prominent in low-temperature environments. Aging of sampling filter capacitors changes the resistor-capacitor time constant and increases voltage sampling delay by 20 ms to 50 ms, affecting voltage monitoring accuracy and response speed.
  • Power device degradation. As the core power device of the controller, the IGBT shows an increase in conduction voltage drop from an initial 2.0 V to 2.4–2.8 V, an increase of 20 percent to 40 percent. Switching losses increase significantly, the junction temperature margin decreases, and switching frequency or output current must be limited to maintain normal operation. Aging of the drive circuit increases gate voltage fluctuation and worsens IGBT switching consistency. Long-term operation also reduces thermal grease in the IGBT, sharply lowering heat dissipation characteristics and making local heat accumulation more likely.
  • Incomplete control algorithms and protection logic. Early controllers used a single current-loop control strategy, in which output current rises with the DC bus voltage and there is no coordinated voltage-current control mechanism. Overcurrent protection relied only on hardware protection and lacked software graded protection, resulting in weak response to transient overload and a greater chance of power device damage from excessive transient stress.

These aging effects are not isolated. Voltage sampling drift can cause the controller to misjudge the state of the power battery and the DC bus. Power device degradation reduces the thermal margin available for the higher losses that come with a higher-voltage power battery. Incomplete control logic can allow current to rise more than necessary when the bus voltage increases. Together, these factors create a controller that may pass basic functional checks but cannot sustain the same thermal and electrical stress as a new controller when paired with a new power battery.

4. Voltage Mismatch Types and Risk Mechanisms

The study classifies voltage mismatch between a new power battery and an aged controller into overvoltage risk, undervoltage risk and thermal risk associated with rated voltage increase. Each type has a distinct mechanism and a different matching response.

  • Overvoltage risk. Overvoltage has two cases. In the first, the voltage exceeds the controller hardware operating range, such as when the three-phase output peak gate voltage exceeds its rated value of 1,200 V. This causes hardware overvoltage damage, and matching requires lowering the rated voltage of the power battery. In the second, the voltage exceeds the controller software setting but remains within the hardware range. In this case, the controller software parameters can be adjusted for adaptation.
  • Undervoltage risk. Undervoltage also has two cases. In the first, the discharge terminal voltage of the power battery falls below the lower limit of the controller hardware range, or an instantaneous voltage drop exceeds the controller tolerance, causing insufficient motor output or shutdown. Matching requires a power battery with a higher rated voltage so that the full state-of-charge range meets requirements. In the second, the voltage falls below the software setting but remains within the hardware range, and the system automatically triggers shutdown protection, affecting driving safety. This can be addressed by adjusting controller software parameters.
  • Rated voltage increase within hardware and software ranges. A higher rated voltage may remain within both hardware and software limits and still cause problems. The reasons include lower internal resistance of the new power battery, aging controller components and incomplete early control logic. Aging components are mainly reflected in reduced IGBT thermal grease and poorer heat dissipation, so heat cannot be removed in time and local heat accumulation occurs, causing IGBT junction temperature to rise continuously. The controller then generates more heat and cannot operate for long periods or at high power. The study focuses on this situation in detail, and matching can be improved by adjusting controller parameters and optimizing thermal management strategies.

The risk mechanism shows why power battery replacement can produce failures even when voltage readings appear acceptable. The new power battery may raise the bus voltage within a declared range, but the controller’s losses are not constant with voltage. Switching losses increase with bus voltage, and conduction losses increase with starting peak current and device junction temperature. An aged controller with reduced thermal grease has less ability to remove that additional heat. The result is a thermal margin problem that manifests as an electrical fault. The study therefore treats temperature rise as a central matching parameter, not a secondary concern.

5. Fault Investigation and Root-Cause Analysis

The fleet fault was mainly manifested as IGBT damage inside the controller. The study investigated several possible causes: aging damage of the IGBT itself, controller overvoltage, overtemperature, and abnormal operation caused by an aging motor. The investigation was structured to eliminate each possibility in turn.

First, to determine whether IGBT damage was caused by product aging, the study conducted appearance inspection, electrical characteristic testing, ultrasonic scanning, internal observation, aluminum wire pull testing and dynamic characteristic testing on IGBTs that had operated for eight years. The test results showed no obvious deterioration of power characteristics, indicating that IGBT aging was not the main factor causing the fault.

Second, to determine whether IGBT damage was caused by overvoltage, the study tested the three-phase output peak gate voltage of the aged controller at different rated voltages. The results showed that at 600 V and 700 V, the peak gate voltages were 744 V and 840 V, respectively, both within limits.

Third, to clarify the effect of rated voltage change on controller heat dissipation, the study carried out temperature-rise tests on the aged controller under rated and peak conditions at 460 V and 600 V. During testing, the cooling system water flow was controlled at 14.8–15.2 L/min to ensure consistent cooling conditions. Under both rated voltages, the controller temperature-rise trend was basically the same, showing rapid heating in the early stage and gradual approach to thermal equilibrium later. As the rated voltage increased, however, overall controller loss and temperature rise increased significantly, and the three-phase temperature difference increased slightly. Under rated conditions, the controller equilibrium temperature was about 66.6 °C on the 460 V platform and about 68.6 °C on the 600 V platform, a temperature-rise difference of about 2 °C. Under peak conditions, the maximum controller temperature was about 85.0 °C on the 460 V platform and about 90.0 °C on the 600 V platform, a temperature-rise difference of about 5 °C. In all rated voltages and operating conditions, the U-phase IGBT temperature was always the highest among the three phases, indicating relatively greater thermal stress, which was highly consistent with the subsequent disassembly finding that U-phase IGBT failure was the most obvious.

Fourth, to verify whether motor aging and abnormal operation were causes of the batch IGBT burnout, the study conducted bench tests on the drive motor that had operated for eight years, focusing on torque output, efficiency and thermal stability. The test results showed that the drive motor could stably output about 700 N·m of continuous torque and about 2,000 N·m of peak torque for short periods, fully meeting the requirements of continuous operation and short-term heavy-load conditions such as starting and climbing. Motor and system efficiency remained stable at 95 percent to 98 percent under most operating conditions, with only brief declines under extreme dynamic conditions such as peak torque and torque release, followed by rapid recovery, consistent with the loss characteristics of the drive motor system. These results indicate that the aging motor’s power output, efficiency and thermal stability basically met design requirements and were not the cause of the fault.

Test condition 460 V platform temperature 600 V platform temperature Difference
Rated condition, controller equilibrium temperature About 66.6 °C About 68.6 °C About 2 °C
Peak condition, maximum controller temperature About 85.0 °C About 90.0 °C About 5 °C

Combining the test results and fault disassembly analysis, the study identifies the core root cause of the batch IGBT burnout. After power battery replacement, the bus voltage increased from 460 V to 600 V. Although this did not exceed the original controller’s wide voltage design range of 350 V to 720 V, IGBT switching loss increases approximately linearly with bus voltage, and conduction loss increases with starting peak current and device junction temperature. As a result, overall IGBT loss increased and more heat was generated than on the 460 V platform.

For a controller with sufficient thermal grease and normal heat dissipation, the heat from the additional loss could be removed by the cooling system in time and would not produce heat accumulation. In this batch of vehicles, however, the IGBT thermal grease in the aged controller had decreased significantly due to long-term operation, and heat dissipation efficiency had dropped sharply. The increased loss on the 600 V platform further intensified heat accumulation, causing IGBT junction temperature to rise faster, peak temperature to increase and device reliability to decline. Under repeated long-term starting peak conditions, U-phase IGBT batch burnout eventually occurred. In addition, voltage sampling drift and incomplete control algorithms in the aged controller further increased the probability of failure, leading to concentrated fault outbreaks.

The root-cause analysis is important for power battery replacement because it separates the power battery from the failure mechanism. The new power battery did not fail in the conventional sense, and the controller voltage range was not exceeded. The failure emerged from the interaction between a new power battery that could deliver current more readily, a higher bus voltage that increased switching loss, and an aged controller whose thermal path had deteriorated. The study’s evidence shows that the U-phase IGBT was consistently the hottest and that the failure location matched the thermal stress pattern. That alignment strengthens the conclusion that thermal margin, not nominal voltage alone, determined the outcome.

6. Engineering Improvements and Validation Results

Against the core cause of the fault, namely reduced IGBT thermal grease and insufficient heat dissipation combined with increased loss after rated voltage rise and insufficient sampling and control precision, the study developed targeted engineering improvement strategies for the practical conditions of power battery replacement in new energy buses. The strategies were designed without replacing the controller and while controlling retrofit costs for bus operators. They focus on heat dissipation optimization, control strategy improvement and parameter calibration to extend the service life of the aged controller and ensure reliable operation at a rated voltage of 600 V.

  • Optimize the IGBT heat dissipation system. Disassemble the IGBT module of the aged controller, clean residual thermal grease and apply a sufficient amount of thermal grease evenly to fill all gaps between the IGBT chip and the heat sink substrate, reducing contact thermal resistance and improving heat dissipation efficiency. Clean dust, oil and other impurities from the heat sink surface to ensure cleanliness and improve heat dissipation reliability.
  • Improve controller protection logic. On the basis of existing hardware protection, add a software graded overcurrent protection strategy that sets different protection thresholds according to the degree of current overload and realizes three-level protection of warning, derating and shutdown, reducing cumulative damage to controller hardware. Optimize the coordinated voltage-current control algorithm, correct voltage sampling drift error and suppress excessive increase of output current with rated voltage, ensuring stable current output and avoiding IGBT overload.
  • Optimize the heat dissipation control strategy. Improve the controller cooling system by adjusting the start and stop logic of water-cooling and air-cooling devices so that cooling starts earlier. Lower the cooling start threshold by 5 °C and extend cooling system operation time to ensure that heat generated by the IGBT is removed in time and heat accumulation is avoided. Check cooling lines regularly to ensure water flow remains stable at 14.8–15.2 L/min without blockage or leakage.
  • Calibrate reasonable current limiting. While meeting the normal operating requirements of the bus, apply reasonable current limiting to the motor and controller system to reduce the thermal stress of starting peak current on the IGBT, reduce controller heat accumulation and balance vehicle dynamic performance with controller reliability.

After implementing these measures on the batch of vehicle controllers, the study carried out bench tests and actual operation verification to check the effectiveness of the improvement strategy. Bench test results showed that at a rated voltage of 600 V, the controller equilibrium temperature under rated conditions dropped to 65 °C, 3.6 °C lower than before improvement. Under peak conditions, the maximum IGBT temperature dropped to 83.5 °C, 6.5 °C lower than before improvement. The three-phase temperature difference was controlled within 2 °C, and IGBT junction temperature remained within the safe range.

Operating condition Temperature before improvement Temperature after improvement Temperature reduction
Rated condition 68.6 °C 65.0 °C 3.6 °C
Peak condition 90.0 °C 83.5 °C 6.5 °C

In actual operation verification, the retrofitted vehicles underwent one month of normalized operation testing, with more than 1,000 vehicle starting conditions accumulated during the test period. During the test period, the vehicles did not experience IGBT burnout or other controller faults. Motor output power and range met operational requirements, and energy consumption per kilometer was lower than before improvement. The results show that the improvement measures effectively solved the problem of insufficient heat dissipation and achieved stable matching between the aged controller and the new power battery at a rated voltage of 600 V, meeting the expected improvement goal.

The validation results are significant for power battery replacement programs because they show that the problem can be addressed without a full controller replacement. The measures are relatively low in cost and practical for fleet retrofits. Reapplying thermal grease restores a critical thermal path. Software graded protection and coordinated voltage-current control reduce the electrical stress that accompanies a new power battery. Earlier cooling activation and verified water flow improve heat removal. Reasonable current limiting reduces the peak thermal load during starting. Together, these measures create a thermal and control margin that the aged controller lacked when paired with the new power battery.

7. Industry Implications for power battery Replacement and Aged Controller Retrofits

The study’s findings have broad implications for the new energy bus industry as more fleets approach power battery replacement. The first implication is that power battery replacement should be treated as a system-level matching project. The new power battery introduces a different electrical source, and the aged controller introduces a different load and thermal path. A successful replacement therefore requires more than confirming voltage compatibility. It requires checking the controller’s voltage sampling accuracy, power device thermal condition, cooling system performance and protection logic.

The second implication is that thermal condition should be inspected directly. The study found that reduced IGBT thermal grease was a key factor. In fleet maintenance, thermal interface condition is often invisible during normal operation and may not be captured by standard diagnostic codes. A power battery replacement program can therefore include inspection and renewal of thermal grease, cleaning of heat sink surfaces and verification of cooling flow. These steps are relatively simple but can materially change the thermal margin of an aged controller paired with a new power battery.

The third implication is that software protection must evolve with the power battery. Early controllers with a single current loop and hardware-only overcurrent protection may not provide enough graded response to transient overload. Adding software graded protection and coordinated voltage-current control can reduce cumulative damage and suppress excessive current under higher bus voltage. For a new power battery with lower internal resistance and stronger voltage stability, the controller must be able to regulate current precisely so that the power battery’s capability does not become an excessive stress on aged power devices.

The fourth implication is that cooling strategy can be calibrated for the new operating point. Lowering the cooling start threshold by 5 °C and extending cooling operation are practical measures that increase thermal margin without redesigning the entire cooling system. Maintaining water flow at 14.8–15.2 L/min and checking for blockage or leakage are equally important. In a power battery replacement project, cooling system verification should be part of commissioning rather than an afterthought.

The fifth implication is that current limiting can balance performance and reliability. Buses need sufficient torque for starting and climbing, but the peak current can impose high thermal stress on aged IGBTs. Reasonable current limiting can reduce that stress while still meeting normal operating requirements. The study’s validation showed that vehicles continued to meet motor output power and range requirements after improvement, while energy consumption per kilometer was lower than before. That outcome supports a practical approach: optimize the thermal and control system first, then calibrate current limits to the actual duty cycle.

The study also points to a gap in industry standards. Different aged controllers have significantly different voltage adaptation thresholds, and quantitative standards in the industry are still lacking. The research plans to carry out quantitative matching tests and form transferable technical specifications. For now, the case provides a reference for in-service controller life extension, fault troubleshooting and power battery replacement. It shows that the question is not simply whether a new power battery’s voltage is within a controller’s declared range, but whether the controller can manage the associated current, loss and heat over repeated operating cycles.

For bus operators, the practical lesson is to sequence power battery replacement with controller health assessment. A new power battery can expose an aged controller that appeared functional with the old power battery. Before replacement, operators can review controller age, thermal maintenance history, voltage sampling performance and cooling system condition. During replacement, they can verify software protection settings and cooling activation logic. After replacement, they can monitor temperature rise under rated and peak conditions and confirm that three-phase temperature differences remain controlled. These steps can reduce the risk of batch failures and improve the overall return on power battery replacement investment.

For system integrators and maintenance teams, the study reinforces the value of root-cause analysis. In the fleet case, IGBT aging, overvoltage and motor aging were each investigated and ruled out as primary causes. The decisive evidence came from temperature-rise testing at different rated voltages and from disassembly findings that matched the U-phase thermal stress pattern. That method can be adapted to other power battery replacement projects: compare the new power battery characteristics with the old power battery, test the aged controller at the new voltage, measure temperature rise under rated and peak conditions, inspect thermal interfaces and validate improvements in actual operation.

8. Conclusion: power battery Matching Requires Integrated Thermal and Control Strategy

The study concludes that the batch IGBT burnout after power battery replacement was caused by a mismatch between the high-voltage sensitivity of the new power battery and the performance degradation of the aged controller. The mismatch increased IGBT loss and worsened heat dissipation, causing peak junction temperature to exceed limits and leading to thermal breakdown. The evidence showed that the new power battery raised the bus voltage within the controller’s wide voltage range, but the aged controller’s reduced thermal grease and degraded thermal path could not remove the additional heat. Voltage sampling drift and incomplete control logic further increased the probability of failure.

The proposed solution combines heat dissipation optimization, software graded protection and current limiting calibration. The study reports that this combination effectively suppressed temperature rise and reduced loss without replacing the entire controller. The approach is low in cost and engineering feasibility is strong. It provides support for life extension retrofits and fault troubleshooting of in-service controllers, and it offers a practical reference for power battery replacement in new energy buses.

The research also identifies remaining work. Different aged controllers have significantly different voltage adaptation thresholds, and industry quantitative standards are still lacking. Future work will carry out quantitative matching tests and form transferable technical specifications. Until such standards are available, the case demonstrates that power battery replacement should be managed through an integrated strategy that considers the new power battery’s voltage characteristics, the aged controller’s sampling and protection performance, the thermal interface condition and the cooling system’s ability to remove heat under real duty cycles.

The broader message is that the power battery is not an isolated replacement part. In an aged bus, the power battery interacts with the controller, motor, cooling system and protection software. A new power battery can improve energy capacity and voltage stability, but it can also shift the operating point of an aged controller toward higher current and higher loss. By measuring temperature rise, inspecting thermal paths, updating protection logic and calibrating current limits, fleet operators can achieve stable matching between a new power battery and an aged controller. The study’s results provide a technical basis for that work and a practical path for extending the service life of existing electronic controls during the growing wave of power battery replacement.

Scroll to Top