A newly published design study has introduced a current detection unit for power battery systems that its authors say delivers measurement accuracy above 99% at currents greater than 20 A, while holding error to 0.5% or less across most of the 5 A to 300 A operating range. The work, carried out by a research team at Saike Ruipu Power Battery System Co., Ltd. in Liuzhou, Guangxi, was published in the 2026, Issue 10 edition of the journal Auto Electric Parts under the title “Design and Implementation of Current Detection Unit for Power Batteries.”
The authors — Lan Yun, Huang Shicong, Lan Yijin, Xiao Yingui and Zeng Qihan — argue that current is the parameter that most directly reflects charging and discharging behavior, energy throughput and thermal behavior inside a power battery, and that the precision, speed and reliability of current detection directly govern the accuracy of state estimation algorithms, including State of Charge (SOC), State of Power (SOP) and State of Health (SOH), as well as the safety control strategies executed by the battery management system. Their proposed circuit combines a high-precision differential amplifier with a low-temperature-drift shunt resistor and is organized into four functional blocks. The paper examines the working principle of each block and reports surge, zero-drift and static accuracy test results obtained from the assembled hardware.
According to the study, the architecture is intended not only as a feasible hardware solution for highly reliable power battery management systems but also as a reference point for sensor design in complex automotive application environments, where electrical transients, wide temperature swings and electromagnetic interference are routine rather than exceptional conditions.
- Why Current Detection Accuracy Matters in a Power Battery
The research team frames the problem by noting that as electric vehicles and stationary energy storage systems expand in scale, precise current detection for the power battery has become a key element in guaranteeing system safety and improving energy management efficiency. An inaccurate current reading propagates directly into every downstream calculation performed inside a power battery management system: the coulomb-counting component of SOC estimation, the power-limiting logic behind SOP, and the cumulative degradation models that support SOH assessment.
Among the available techniques, the shunt resistor approach — often described as the resistance sampling method — retains a decisive cost advantage and has therefore become the first choice for current detection in production power battery systems. The method measures the voltage developed across a calibrated resistor placed in the current path and infers current from Ohm’s law.
Placement of that resistor divides the technique into two variants. In the high-side configuration, the sampling resistor sits between the power source and the load; the approach avoids introducing ground disturbance and can identify a load-to-ground short circuit fault, but it exhibits comparatively weak immunity to common-mode interference. In the low-side configuration, the sampling resistor sits between the load and ground; the common-mode voltage is close to zero, but the arrangement introduces ground disturbance and cannot detect a load-to-ground short circuit.
Because both variants carry inherent trade-offs, the team argues that developing a new resistance-sampling current detection circuit for the power battery domain carries substantial practical significance. The proposed unit is described as being able to serve high-side and low-side scenarios simultaneously, exploiting the wide common-mode input voltage range of the INA186A2 operational amplifier to adapt to either shunt placement without a redesign of the sensing chain.
Three design objectives shaped the circuit: suppression of common-mode noise through a robust amplifier, reduction of random error through a multi-channel acquisition scheme, and verification of robustness and real-time behavior under complex operating conditions. The authors position the resulting unit as a new solution option for power battery management systems facing increasingly demanding accuracy and safety requirements.
- Overall Hardware Architecture of the Power Battery Sensing Unit
The detection unit is built around four principal hardware blocks: the shunt resistor itself, a signal amplification and conditioning circuit, an isolation circuit and a communication interface circuit. Component selection spans several suppliers. The main controller is the HC32F4A from Huada Semiconductor. The analog front end (AFE) KA84933UA and the isolated communication transceiver KA84921UA, both from Nuvoton Technology, form the isolation module. The operational amplifier is the INA186A2 from Texas Instruments.

Within this architecture, the signal chain begins at the shunt, passes through differential amplification, is digitized by the analog front end on the high-voltage side, crosses an isolation barrier, and is finally consumed by the main controller, which executes the core battery management algorithms of the power battery system. The division of labor is deliberate: the analog front end handles acquisition close to the high-voltage domain, the isolation stage protects the low-voltage control domain, and the main controller concentrates on computation and network communication.
This partitioning matters in a power battery context, where the sensing electronics must coexist with high-voltage busbars, switching power stages and the electromagnetic emissions they generate. Keeping the analog acquisition on the high-voltage side and confining the crossing of the isolation barrier to digital communication reduces the opportunity for noise to contaminate a low-level analog signal.
- Shunt Resistor Selection: Balancing Signal Strength Against Power Dissipation
The paper is explicit about the trade-off governing shunt selection. At the maximum measured current, a larger voltage drop across the shunt produces a stronger signal relative to the noise floor of the measurement system — which includes the quantization noise of the analog-to-digital converter and the input offset voltage of the operational amplifier — and measurement accuracy rises accordingly. The same larger voltage drop, however, increases the power dissipated by the component itself.
The target application is a circuit rated for continuous currents of up to plus or minus 350 A. For that duty, the design team selected the GFLEV8520C shunt, with a resistance of 0.1 mΩ, a resistance tolerance of plus or minus 0.5%, a temperature coefficient of no more than 75 × 10⁻⁶ °C⁻¹, and a rated power of 12.5 W. The component is described as stable in operation under long-term service and environmental stress, a property that matters for a power battery application in which the sensor is expected to remain in the field for the life of the vehicle or storage installation.
At a 0.1 mΩ resistance, a 350 A current develops only 35 mV across the shunt while dissipating approximately 12.25 W, which sits just inside the 12.5 W rating of the device. That arithmetic underlines why the amplifier’s offset and drift characteristics become decisive: the full-scale signal is small enough that errors at the amplifier input are not negligible relative to the quantity being measured.
- Signal Conditioning, Multi-Channel Acquisition and Transient Protection
The signal conditioning circuit applies a differential amplifier stage with a gain of 50 to the voltage developed across the shunt. Rather than relying on a single conversion, the system uses three channels of the analog front end — designated GPIO8, GPIO9 and GPIO11 — to acquire the shunt voltage, and two further channels — GPIO7 and GPIO12 — to acquire the reference supply voltage. The redundancy is intended to reduce random error and raise overall system measurement accuracy.
The chosen amplifier, the INA186A2, offers a wide common-mode voltage range of -0.2 V to 40 V, a common-mode rejection ratio of up to 120 dB, an offset voltage of plus or minus 50 μV, a gain drift of 10 × 10⁻⁶ °C⁻¹ and an offset drift of only 0.5 μV/°C. Its low input bias current permits the use of relatively large current-sensing resistors while still supporting microampere-level precision. For a power battery sensing chain, the combination of wide common-mode range and high common-mode rejection is what allows the same circuit to operate with the shunt placed on either side of the load.
The paper also documents the protection strategy applied ahead of the amplifier. When components are used in accordance with the recommendations of the official datasheet, the risk of damage or abnormal operation inside the loop is low in most circumstances. In complex automotive electronic application scenarios, however, basic risk-mitigation design and preventive measures remain necessary. For input voltages that may exceed the rated value, the design adds transient voltage suppressors (TVS) at the input front end, together with protection resistors R1 and R2 and input capacitors C1 and C2.
TVS devices are widely used in sensitive electronic equipment to guard against voltage transients caused by inductive load switching and startup, and they are particularly applicable to automotive load-dump protection. Single-polarity or bidirectional devices can be selected according to system requirements. In this circuit, the TVS must complete voltage clamping before the input voltage reaches the maximum input voltage allowed by the amplifier; accounting for the reaction time required for the TVS clamping voltage, R2 is placed to limit the current flowing into the downstream circuit. Limiting the input current to within 5 mA is generally sufficient to prevent damage to the downstream circuit from an electrical overstress event, and the paper presents the corresponding resistance selection relationship.
A second condition applies to negative surge voltages. The design uses a unidirectional TVS; when the system is subjected to a negative voltage, the device conducts in forward bias, and the resulting forward bias voltage must remain above the minimum common-mode voltage permitted by the amplifier. For negative surge events, therefore, R2 must additionally be sized to limit the current entering the downstream circuit. R1 in turn limits the current flowing into the TVS, reducing the power rating the suppressor must carry.
Temperature variation can introduce offset voltage error into the circuit. Mismatched leakage currents in the loop can develop a voltage drop across R1, producing an input offset voltage error. Following the datasheet recommendation, the total input resistance (R1 + R2) must remain below 10 Ω to avoid excessive system offset voltage arising from excessive input impedance and degrading measurement accuracy. The design adopts R1 + R2 = 10 Ω as the critical value, and the authors note that PCB layout must strictly control leakage current in the input loop to prevent additional offset error. Input capacitors C1 and C2 suppress fast voltage surges, improving test stability and noise immunity.
- Isolation and Communication Interface in the Power Battery Management Path
The isolated communication transceiver KA84921UA establishes an isolated communication channel between the high-voltage-side analog front end and the low-voltage-side processor HC32F4A. That channel ensures electrical noise and hazardous voltages on the high-voltage side are not transferred to the low-voltage control side while data is still passed reliably across the barrier. In a power battery installation, this separation is a safety requirement as much as a signal-integrity measure.
From the perspective of the low-voltage processor, the KA84921UA presents itself as a standard SPI slave device. The processor acts as the SPI master, controlling the chip-select signal and the clock signal and sending commands to the transceiver over the MOSI line; the transceiver returns response data from the analog front end to the processor over the MISO line. The arrangement keeps the interface conventional and portable across controller families.
Once data acquisition is complete, the HC32F4A runs the core battery management algorithms of the power battery system: SOC estimation, SOP estimation, SOH estimation and fault diagnosis. The processor then transmits the key information it has computed — total current, SOC, SOH and fault codes among them — to the vehicle network through its integrated CAN controller, using the CAN protocol format. The current detection unit therefore does not terminate in a standalone measurement; it feeds the network that coordinates the power battery with the rest of the vehicle.
- Transient Surge Simulation and Immunity Testing
To identify the optimal protection circuit configuration, the team ran simulation tests on 10 different configurations. Configuration 5 was reported as delivering the best response and surge withstand capability, with currents flowing through D1 and D2 both within the specified range and the system operating normally, and with the ISENSE+ and ISENSE- input voltages also remaining within range. In that configuration, C1 is specified at 1 μF, 25 V; C2 at 7 μF, 16 V; D1 as an SMBJ5.0A; and D2 as an ESDBKV5V0D.
The simulation configurations explored are summarized below.
Configuration R1 (Ω) R2 (Ω) D1/D2 C1/C2 1 — — — — 2 5 5 D1 C1 & C2 3 7 3 D2 C1 & C2 4 7 3 D1 C1 & C2 5 1 9 D1 C1 & C2 6 10 0 D2 — 7 10 0 D2 C1 & C2 8 0 5 D1 C1 & C2 9 0 3 D2 C1 & C2 10 0 3 D1 C1 & C2 The configurations were then subjected to transient surge testing in accordance with GB/T 17626.5—2019. The results show that the weakest component in the loop is R1. The value of R2 had only a minor influence on the test outcome, which allowed the designers to set R2 at its minimum value of 1 Ω in order to reduce input gain error. When the signal duration is on the order of milliseconds, C1 and C2 contribute nothing to system protection. The components that play the decisive role in transient overvoltage protection of the amplifier are the TVS diodes D1 and D2, and the stability and robustness of the entire transient protection circuit depend on the current the TVS devices can absorb, on the PCB and on system design cost. The final configuration selected for the system is R1 = 9 Ω, R2 = 1 Ω, D1/D2 = SMBJ5.0A, C1 = 1 μF, 25 V and C2 = 7 μF, 16 V.
Configuration Pass Fail Damaged component 1 Not passed 200 V, 50 Ω INA186A 2 220 V, 10 Ω 250 V, 10 Ω R1 3 — 220 V, 10 Ω R1 4 250 V, 10 Ω 300 V, 10 Ω R1 5 400 V, 10 Ω 500 V, 10 Ω R1 6 300 V, 10 Ω 350 V, 10 Ω R1 7 300 V, 10 Ω 400 V, 10 Ω R1 8 — 200 V, 10 Ω R1 9 3 kV, 2 Ω 4 kV, 2 Ω D1 & D2 10 250 V, 10 Ω 300 V, 10 Ω D1 & D2 The test matrix makes the contribution of the protection network visible. The unprotected configuration failed at 200 V with a 50 Ω source impedance and destroyed the INA186A amplifier outright. Configurations that combined a resistor network with a TVS device pushed the withstand threshold upward, with configuration 5 passing at 400 V, 10 Ω and failing at 500 V, 10 Ω by damaging R1. Configurations 9 and 10, which omitted R1, shifted the failure mode to the TVS diodes themselves. For a power battery system installed in a vehicle, where load-dump and inductive switching transients are realistic hazards, the difference between a protected and an unprotected front end is the difference between a recoverable disturbance and a failed sensor.
- Zero-Drift Behavior and Static Accuracy Results
Zero-drift testing was carried out with the ISENSE+ and ISENSE- inputs shorted together. The tests revealed a zero-drift current of 0 to 0.3 A in the system. Zero drift changes slowly with time, ambient temperature, supply voltage and other conditions. It is a systematic issue resulting from the combined action of multiple physical effects and component imperfections.
Beyond careful component selection, optimized circuit design and refined PCB layout, the authors emphasize that software optimization strategies are indispensable. Building on that foundation, the team optimized the software model and added an adaptive zero-drift calibration module, which enables effective suppression of drift. The reported drift range is significant for a power battery management system because a persistent 0.3 A offset accumulates under coulomb counting and, if left uncorrected, slowly biases SOC estimation away from the true value over long rest and charge cycles.
Static accuracy testing was performed at room temperature. A 12 V supply was connected to the system and the unit was brought into its wake-up operating state. The system was connected to a host computer over the CAN bus, a constant current source was connected to the shunt, and the current source output was adjusted to each preset constant current. Software on the host computer recorded the displayed current, which was then compared against the actual applied current. Ten different current values were tested.
Test current (A) Constant current source, 30-minute average (A) Shunt, 30-minute average (A) Error (%) 300 299.81 300.2 0.13 250 249.83 250.0 0.07 200 200.09 200.2 0.05 150 149.86 150.2 0.23 100 100.12 100.4 0.28 75 75.01 75.4 0.52 50 50.14 50.2 0.12 20 20.2 20.4 0.99 5 4.99 5.2 4.21 1 1.12 1.4 25 The results confirm that system accuracy deteriorates markedly when measuring currents below 5 A. Possible contributing factors include thermoelectromotive force, external noise and the temperature coefficient of the components. Achieving higher accuracy at small currents would require additional filtering circuitry and temperature compensation of the sampling resistor, measures that the study identifies as subjects for further work rather than elements of the current design.
Across the upper portion of the range, the picture is considerably stronger. In the 20 A to 300 A interval, the overwhelming majority of test points showed measurement error at or below 0.5%, with only an individual test point marginally exceeding that figure — the 75 A point, at 0.52%. At 20 A the error was 0.99%, corresponding to measurement accuracy of just over 99%. For a power battery system operating in its normal traction and charging envelope, that is the region where accuracy matters most, because it is where the bulk of energy throughput is exchanged and where current readings feed directly into power-limiting and protection decisions.
- What the Results Mean for Power Battery System Design
The authors conclude that they have designed a new and reliable current acquisition system based on an analog front end and a differential amplifier. The measured performance, they state, holds error at or below 0.55% for the great majority of test points in the 20 A to 300 A range, with only isolated points slightly outside 0.5%; in the 5 A to 20 A range, error increases under the influence of thermoelectromotive force and environmental noise. The hardware and software design is described as concise, flexible and highly reliable, and the circuit is judged suitable for application in power battery management systems.
Several design decisions stand out as transferable lessons for engineers working on power battery sensing. The first is the deliberate use of an amplifier with a wide common-mode input range, which converts a placement constraint into a design choice and allows a single hardware platform to address both high-side and low-side shunt arrangements. The second is the multi-channel acquisition scheme, in which three channels read the shunt voltage and two read the reference supply, a straightforward redundancy that reduces random error without altering the analog front end. The third is the treatment of the input protection network as a tuned system rather than a collection of parts, with resistor values selected against measured surge thresholds and the total input resistance constrained to keep offset error within bounds.
The paper is equally clear about what remains unresolved. Thermoelectromotive force, external noise and temperature coefficient are identified as the factors limiting accuracy in the sub-5 A range, and the authors state that related optimization and improvement work requires further study. For a power battery management system, that limitation is not trivial: small currents dominate long rest periods, low-rate balancing and certain fault signatures, and a drift of several percent in that region can obscure the slowly developing conditions that predictive diagnostics are meant to catch.
- Outlook for Power Battery Current Sensing
The broader significance of the work lies in its framing of current detection as a system-level problem in the power battery rather than a component-level one. Accuracy depends jointly on shunt tolerance and temperature coefficient, amplifier offset and drift, analog-to-digital conversion noise, protection network leakage, PCB layout and the calibration model running in software. The paper addresses each of these layers, and its reported results reflect the combined effect rather than the performance of any single part.
That layered approach is likely to become more important as power battery systems move toward higher voltage platforms, faster charging rates and more demanding safety certification. Each of those trends raises the dynamic range the sensing chain must cover and tightens the error budget available at the low end. The adaptive zero-drift calibration module described in the study points toward a practical direction: rather than pursuing precision exclusively through component selection, the design pairs careful analog engineering with software correction that can track drift over the service life of the power battery.
The published results provide a documented baseline for that effort. Within the 20 A to 300 A band the unit holds error to 0.5% or less at nearly every point tested; at currents below 20 A the error grows, and the paper names the physical mechanisms responsible. For designers specifying current detection in a power battery management system, both halves of that statement carry practical value.