1. Introduction
With the global push towards carbon neutrality and the electrification of transportation, the market demand for electric cars has surged dramatically. As the core energy source of electric cars, the traction battery system is undergoing unprecedented opportunities and challenges. Lithium-ion batteries with high cycle life are currently the most extensively adopted type of power battery in the industry. However, as the fast-charging technology and the discharge rates escalate, lithium-ion batteries are facing increasingly stringent safety and reliability requirements for their operation across diverse driving conditions. A stable and efficient battery cooling system is the core solution to meet these challenging demands.
Among various cooling technologies, the hybrid cooling system that integrates liquid cooling with phase change materials (PCMs) has demonstrated significant application prospects in battery thermal management due to its high efficiency and stability. Addressing the design of a cylindrical battery module cooling system, my research aims to propose innovative solutions to investigate the cooling performance, temperature uniformity, and the thermal management of the battery pack under various discharge regimes of electric cars.

In this research, I analyzed the attributes and characteristics of commonly used power battery types in electric cars, selecting the 21700 cylindrical battery as the research target. Building on the extensive review of battery heat generation and heat transfer mechanisms, I established a battery model by combining experiments with numerical analysis. Afterwards, I optimized the liquid cooling system design under normal 2C discharge conditions, and finally, for the high-rate discharge scenario, a novel compound cooling structure was developed and optimized by using advanced surrogate models and multi-objective optimization algorithms.
2. Structure and Thermal Characteristics of Lithium-ion Batteries for Electric Cars
Depending on the packaging format, the batteries used in electric cars can mainly be categorized into cylindrical, prismatic, and pouch types. Cylindrical lithium-ion batteries, such as the 21700 model, are characterized by high standardization, mature manufacturing processes, low integration costs, and flexible arrangement options. Their cylindrical shape creates inherent gaps between cells, which is conducive to thermal dissipation and higher safety. As the electrification in electric cars advances, the 21700 battery has become one of the most common cell formats for high-performance models, thus it was chosen as my research object. The specific parameters of the cell are shown in the table below.
| Parameter | Value |
|---|---|
| Nominal Capacity / Min Capacity | 5000 mAh / 4900 mAh |
| Nominal Voltage / Charging Voltage | 3.7 V / 4.2 ± 0.05 V |
| Discharge Cut-off Voltage | 2.75 V |
| Maximum Discharge Rate | 3C |
| Weight | 68 ± 2 g |
| Dimensions | 21 × 70 mm |
| Operating Temperature Range | -20 ℃ to 60 ℃ |
The battery heat generation mechanism comprises four primary components: electrochemical reaction heat \(Q_r\), ohmic heat \(Q_j\), polarization heat \(Q_p\), and side reaction heat \(Q_s\). The total heat \(Q\) is expressed as Eq. (1):
Q = Q_r + Q_j + Q_p + Q_s
$$
Side reaction heat is negligible in standard operations. The ohmic heat and polarization heat are both generated by the internal resistance of the cell, which can be combined in terms of internal resistance \(R\). The generation rate is widely calculated by the Bernardi model. The equivalent heat generation rate per unit volume \(Q_{gen}\) is represented in Eq. (2):
Q_{gen} = \frac{1}{V_b}\left[ I^2 R + IT \frac{\partial U_{OCV}}{\partial T} \right]
$$
where \(V_b\) is the battery volume, \(I\) denotes the current, \(U_{OCV}\) is the open circuit voltage, and \(T\) is the temperature.
3. Battery Experiments and Construction of the Heat Generation Model
3.1 Experimental Setup
To accurately predict heat generation, I carried out experiments on the selected 21700 cells. The test platform included a power battery testing system (NEWARE), a temperature data acquisition device (Luyi), and a constant temperature chamber (Tinghua). T-type thermocouples were attached to measure the surface temperature precisely.
3.2 HPPC Internal Resistance Test
The internal resistance of a lithium-ion battery is not a constant value; it experiences variations corresponding to the ambient temperature and the state of charge. To map these changes precisely, I applied the Hybrid Pulse Power Characteristic (HPPC) method. The test procedure involved charging the cell to 100% SOC and applying a 10-second discharge pulse at 1C, resting for 40 seconds, then applying a 0.75C charge pulse. Given an open circuit voltage drop, the total internal resistance \(R\) can be calculated as in Eq. (3):
R = R_j + R_p = \frac{U_1 – U_3}{I}
$$
where \(R_j\) denotes the ohmic resistance and \(R_p\) denotes the polarization resistance. I conducted tests at five different ambient temperatures (10°C, 20°C, 25°C, 35°C, and 45°C) and across various SOC levels. The results, as shown in the figures, demonstrated notably high internal resistance values at low ambient temperatures, approaching 60 mΩ at 10 °C; meanwhile, at SOC levels lower than 0.2, the resistance increased, particularly at lower temperatures where it exceeded 100 mΩ at low SOC. Conversely, at temperatures from 35 °C to 45 °C, the internal resistance stabilized around 30 mΩ.
3.3 Polynomial Fitting of Internal Resistance
Given the non-linear relationship between the variables, I fitted the experimental data to a polynomial mathematical model in Matlab. The internal resistance \(R\) was fitted as a polynomial function of temperature \(T\) and state of charge \(SOC\), where \(x\) is the temperature and \(y\) is the SOC, described by Eq. (4):
\begin{aligned}
R = & p_{00} + p_{10}x + p_{01}y + p_{20}x^2 + p_{11}xy + p_{02}y^2 + p_{30}x^3 + p_{21}x^2y + p_{12}xy^2 + p_{03}y^3 \\
& + p_{31}x^3y + p_{22}x^2y^2 + p_{13}xy^3 + p_{04}y^4 + p_{32}x^3y^2 + p_{23}x^2y^3 + p_{14}xy^4 + p_{05}y^5
\end{aligned}
$$
The coefficients of this fitted polynomial model are presented below:
| Coefficient | Value | Coefficient | Value |
|---|---|---|---|
| p00 | 267 | p03 | -7053 |
| p10 | -12.45 | p31 | 0.0061 |
| p01 | -1484 | p22 | 0.871 |
| p20 | 0.268 | p13 | 101 |
| p11 | 54.01 | p04 | 5316 |
| p02 | 4522 | p32 | -0.003 |
| p30 | -0.002 | p23 | -0.286 |
| p21 | -0.882 | p14 | -38.3 |
| p12 | -105.8 | p05 | -1551 |
3.4 Battery Simulation Model
To simplify the complex battery structure, I made several assumptions in my simulation analysis. The internal core was treated as a homogenous cylindrical body with uniform heat generation. The heat transfer coefficients were considered constant and thermal radiation was neglected. The battery thermal characteristics were computed according to the material layers. The effective density \(\rho\), specific heat capacity \(C_p\), and thermal conductivity values in the different directions were calculated using formulas derived from the series and parallel connection of the cell layers:
\rho = \frac{\sum m_i}{\sum V_i}
$$
C_p = \frac{\sum L_i C_{p,i}}{\sum L_i}
$$
\lambda_x = \lambda_y = \frac{\sum L_i}{\sum \frac{L_i}{\lambda_i}}, \quad \lambda_z = \frac{\sum L_i \lambda_i}{\sum L_i}
$$
Where \(L_i\) is the thickness of the i-th layer, \(\lambda\) is the thermal conductivity, \(m\) is the mass, and \(V\) represents the volume. In the CFD simulation, the heat source model was integrated into the Fluent solver. It was verified that at 2C discharge rate, the peak temperature is 44.21 °C; at 3C it reached 51.29 °C.
3.5 Model Validation via Temperature Rise Experiments
To validate the simulation model, I conducted temperature rise experiments under the same conditions as the simulations. The T-type thermocouples monitored the cell surface temperature in real time. According to the experimental results, the simulation results were in good agreement with the experimental data. The maximum absolute error was kept within 2 °C, confirming that the established model could be used for the accurate study of the pack cooling systems.
4. Design and Optimization of Liquid Cooling System for the Pack
4.1 Physical Model and Numerical Setup
In this section, I focused on the thermal management of a module comprising 16 cells arranged in a 2×8 array, discharging at a constant 2C rate. The initial liquid cooling design was a double-sided cold plate structure, containing four rectangular channels on the top and bottom. The module’s geometry and computational domain are defined as follows: total channel length is 204 mm, with each channel cross-section set to 10 mm × 10 mm in size. The spacing between the two rows of cells was designed to be 33 mm, while the gap between adjacent cells was set to 4 mm. For the liquid cold plate, the thickness separating the channel from the upper/lower surface was set to 1 mm. The interval between the neighboring channels was established at 7 mm, and the vertical gap between the top and bottom cold plates was fixed to 6 mm to ensure structural integrity and compactness. The cooling liquid selected for the study was a 50% ethylene glycol aqueous solution (density: 1082 kg/m³), while the cold plate was made of aluminum (thermal conductivity: 202.4 W/m·K). The relevant material parameters are presented below.
| Material | Density (kg/m³) | Specific Heat (J/kg·k) | Thermal Conductivity (W/m·k) |
|---|---|---|---|
| Aluminum | 2719 | 871 | 202.4 |
| 50% Ethylene Glycol | 1082 | 3300 | 0.4 |
The governing equations for the computational domain include the conservation of mass, momentum, and energy:
\frac{\partial \rho}{\partial t} +
abla \cdot (\rho \vec{u}) = 0
$$
\rho \frac{d\vec{u}}{dt} = –
abla p + \mu
abla^2 \vec{u}
$$
At the inlet boundary condition, the maximum flow velocity in the calculation was no more than 0.1 m/s. Based on the calculation results, the Reynolds number (\(Re\)) remained below 2300 across all models, so the laminar flow model was selected. A grid independence verification was performed to ensure the accuracy of the simulation results and to balance the computational cost. The mesh elements were varied from 99,737 to 425,455, and the average battery temperature was used as the evaluation metric. When increasing the grid count to 425,455, the temperature only varied by 0.01°C, indicating mesh independence. This configuration was used for the subsequent simulations.
4.2 Design and Comparison of Wedge Block Configurations
Based on a single-sided optimization strategy, I introduced wedge-shaped structures inside the liquid cooling channels to disturb the flow and improve heat transfer. I considered a smooth channel (no wedge) as the baseline and designed three innovative wedge-type geometries, namely the rectangular wedge (case0), the arc-shaped wedge (case1), the circular wedge (case2), and the inverse arc wedge (case3). The wedge’s basic dimensions were set to 10 mm in length and 5 mm in height. The results for the different designs at the end of the 2C discharge are summarized below:
| Case | Smooth | case0 | case1 | case2 | case3 |
|---|---|---|---|---|---|
| Max Temp (°C) | 35.21 | 35.02 | 34.96 | 34.92 | 35.03 |
| Avg Temp (°C) | 32.94 | 32.67 | 32.61 | 32.59 | 32.68 |
The case2 design achieved the most significant cooling performance. This effect can be attributed to the fact that the wedge creates a constrained flow path, causing a local acceleration of the coolant flow near the wedge tip. This heightened velocity disrupts the thermal boundary layer over the channel surface. Secondly, the wedges induce the formation of recirculation zones behind them. The presence of these zones increases the local turbulence level and promotes mixing of the coolant, thereby enhancing the convective heat transfer coefficient and facilitating more effective heat dissipation from the battery module.
4.3 Effect of Wedge Arrangement Strategies
Based on the optimal wedge shape (case2), I further evaluated the effects of wedge distribution on the overall thermal performance by designing multiple scenarios. The different configurations are described as follows: plan0 corresponds to the smooth initial channel; plan1 and plan2 represent configurations with seven wedges arranged on the same side or placed in a staggered manner on both walls, respectively; plan3, plan4, and plan5 represent the cases with four wedges placed in the front, middle, and rear sections of the channel, respectively.
Based on the results of the temperature changes, I find that the plan2 arrangement achieved the lowest maximum temperature and the most considerable improvement in temperature uniformity. As the flow progresses along the channel, the coolant temperature increases. This increase results in a lower temperature gradient between the coolant and the channel walls near the outlet region, limiting heat transfer effectiveness. The staggered placement of the wedges continuously shifts and redistributes the core of the high-velocity flow across the entire channel width. It prevents the formation of a weak heat transfer zone along the walls.
The comparison of the temperature distribution contours on the walls demonstrated that the staggered arrangement substantially enhanced the heat exchange from the coolant to the channel, leading to more uniform and effective cooling. For the four-wedge configuration placed in the middle and at the rear sections, significant improvement in the overall temperature uniformity was obtained. Since the temperature of the coolant in the latter half of the channel is higher, the addition of wedges there disrupts the thermal boundary layer more effectively, improving the local heat transfer rate and evenness.
4.4 Impact of Channel Number and Inlet/Outlet Arrangement
Following the adoption of the plan2-staggered wedge arrangement, I expanded the design from a single top/bottom cold plate to a double-layer cold plate configuration. I also investigated the influence of cooling channel layouts and fluid flow direction. The battery temperature variations for different channel numbers are presented in the following figures. It was found that increasing the number of cooling channels could effectively reduce the maximum temperature of the module. The spatially separated channels produced the best temperature uniformity.
To further alleviate increasing temperature differences that accompany a larger number of channels, I introduced a dual-layer liquid cooling module. Furthermore, the arrangement of the inlet/outlet positions was compared. An alternating or staggered placement of inlet and outlet was found to be more effective than aligning them on the same side. In the final optimized design, the maximum temperature dropped to 29.84 °C, while the temperature difference was only 4.0 °C under a 2C discharge condition for the electric car battery pack. It is important to note that the introduction of the wedges increases the flow resistance of the channel. The pressure contours show a pressure drop increase when compared with the smooth channel; this economic cost must be considered in a real application.
5. Design and Multi-objective Optimization of Hybrid Cooling System
5.1 System Configuration
When the cells in the electric car undergo a high discharge rate (3C), their heat generation rate increases sharply. In such a scenario, the temperature difference of the module will also expand. To handle this, I proposed a novel hybrid cooling strategy that combines the PCM and a newly designed composite cold plate. The schematic of the physical model is presented in the model illustration. The design contains a 1×6 array of cells, surrounded by PCM blocks. The innovation addresses improving the battery spatial arrangement via a “honeycomb”-inspired structure. Each cell was wrapped within its individual PCM housing with a central angle. High-conductivity aluminum cold plates were tightly integrated into this honeycomb frame, connecting the cells to the coolant.
Notably, I proposed a novel double-layer liquid cold plate design. Each cold plate is folded into a shape that substantially increases the contact area with the surrounding PCM and the battery module. The cold plate inlet and outlet are both located in the upper layer. The fluid channels within the cold plate have a fixed width of 3 mm. The central wall thickness between the incoming and outgoing fluids was set to 0.5 mm. Furthermore, the gap between the upper and lower layers was set at 20 mm. The boundary thickness between the fluid channel and the outer wall of the cold plate was 1 mm. This intelligent distribution enables the cooling channels to cover a much larger surface area of the battery pack in a compact space.
5.2 Numerical Model and Validation
To accurately model the heat absorption behavior within the PCM, I applied the enthalpy-porosity technique. Assuming that no convection occurs in the liquid phase of the PCM, its transient heat transfer is described as follows:
\rho_{PCM} \frac{\partial H}{\partial t} =
abla \cdot (k_{PCM}
abla T)
$$
H = L\beta + \int_{T_0}^{T} C_{p,PCM} dT
$$
where \(\beta\) represents the liquid fraction, which is 0 when the PCM is completely solid and 1 when it is fully liquid. \(L\) is the latent heat of the PCM, and \(k_{PCM}\) denotes its thermal conductivity. Before conducting the parametric study, I carried out a mesh independence test for the hybrid cooling system. The grid cells were refined from 11,336 up to 852,692. As the number increased, the average battery temperature and liquid fraction converged to a stable plateau. Considering the trade-off between the accuracy and the computational cost, I applied a mesh resolution of 383,488 cells for the subsequent numerical analysis.
5.3 Single-Factor Optimization Analysis
To identify the dominant design variables, I carried out systematic single-factor analyses first. The initial ambient conditions were set to 25°C, and the cold plate inlet temperature was 25°C at a flow velocity of 0.05 m/s. I set the cold plate’s unit depth to 8 mm and the cooling channel width to 3 mm. In this stage, I varied the PCM thickness, the cold plate depth, the inlet velocity, and the PCM material types.
5.3.1 Effect of PCM Thickness
I evaluated the performance of the system with a PCM thickness varying from 1 mm to 4 mm. The results show that the temperature uniformity of the cell module was significantly improved compared to that of a pure liquid-cooled module. The maximum temperature difference was reduced from as high as 6.82 °C (without PCM) down to only 1.48 °C when the PCM thickness was 4 mm. This can be attributed to the latent heat storage capability of the PCM. As the PCM absorbs heat, the system enhances the overall heat capacity, effectively buffering the battery temperature rise. However, this comes at the cost of a slower increase in the entire system temperature. It was observed that when the thickness of PCM was increased from 1mm to 4 mm, the liquid fraction decreased from 0.71 to 0.41. This means the utilization rate of the PCM drops; the center portion of the PCM remains solid and is not fully used for energy storage. Considering this trade-off, a baseline of 3 mm thickness is a rational selection for further analyses.
5.3.2 Effect of Cold Plate Depth and Fluid Velocity
I varied the cold plate depth from 8 mm to 16 mm. It was evident from the results that increasing the depth provides a larger heat transfer area and therefore helps in lowering the peak temperature. Yet, the minimum temperature drops faster, and after reaching a depth of 10 mm, the temperature difference tends to rise. An optimal trade-off between maximum temperature and temperature uniformity is obtained for a moderate depth of around 12 mm. Then, I evaluated the influence of the coolant inlet velocity (from 0.05 m/s to 0.15 m/s). The results indicate a fairly limited effect: increasing the inlet velocity tenfold reduces the average max temperature by merely 0.27 °C. This is because the placement of the inlet at the top layer of the cold plate limits the cooling effect in the bottom layers, causing flow localization. The thermal performance is thus not sensitive to flow rate changes at higher velocities.
5.3.3 Effect of Different PCM Types
I tested three widely used commercial PCMs with different phase change temperatures, labeled RT31, RT35, and RT42 in the table below.
| Property | RT31 | RT35 | RT42 |
|---|---|---|---|
| Density (kg·m⁻³) solid/liquid | 830/760 | 860/770 | 880/760 |
| Specific heat (J·kg⁻¹·K⁻¹) | 2000 | 2000 | 2000 |
| Thermal conductivity (W·m⁻¹·K⁻¹) | 0.2 | 0.2 | 0.2 |
| Latent heat (J·kg⁻¹) | 165,000 | 160,000 | 165,000 |
| Melting range (°C) | 29 – 34 | 32 – 38 | 38 – 43 |
The numerical results show that the system using RT31 exhibits the best overall performance, maintaining the battery module temperature below 40 °C. Compared to RT35, it decreased the maximum temperature by about 0.63 °C, lowered the minimum temperature, and effectively minimized the maximum temperature difference to 1.51 °C. In contrast, the module with RT42 had the highest maximum temperature (40.19 °C). This variation is mostly related to the melting point of each phase change material. RT31 starts melting sooner within the discharge time because of its lower phase change point. As the melting phenomenon starts around 200 seconds into the discharge, the peak temperature is actively capped, demonstrating superior thermal buffering. This indicates that the choice of PCM is a key factor in the design.
5.3.4 Effect of Coolant Inlet Temperature
In applications of electric cars, the external environment temperature can often fluctuate. I selected four inlet temperatures, i.e., 15°C, 20°C, 25°C, and 30°C, to study the effects. The average battery temperature increased by about 14.8% when the inlet coolant temperature was raised from the 15°C case to the 30°C case. The higher inlet temperature pre-heats the PCM and assists a more complete melting; the PCM liquid fraction is raised from 0.34 at 15°C to 0.96 at 30 °C, resulting in an almost fully melted state. While the overall average temperature is higher due to the hotter coolant, the temperature uniformity is improved. The maximum temperature difference dropped from 2.25°C to 1.26°C with the rise in inlet temperature. Therefore, I needed to strike a delicate balance between cooling performance and thermal uniformity to achieve robust operation.
5.4 Multi-objective Optimization Analysis
In this hybrid cooling system, the module’s maximum temperature and maximum temperature difference are in conflict with each other. Reducing the temperature difference at the cost of a high maximum temperature or vice versa is not acceptable for a robust thermal management system in electric cars. Hence, I employed a systematic optimization procedure based on the Kriging surrogate model integrated with the NSGA-II genetic algorithm.
5.4.1 Design Variables and Objectives
Based on the sensitive study results, I identified three primary variables for the optimization: the PCM thickness \(D\), the depth of the cold plate \(H\), and the coolant inlet temperature \(T\). The range of these variables is presented below:
| Design variable | Starting point | Range |
|---|---|---|
| PCM thickness D (mm) | 1 | [1, 4] |
| Cold plate depth H (mm) | 8 | [8, 18] |
| Coolant inlet temperature T (°C) | 15 | [15, 25] |
I applied the Latin Hypercube Sampling (LHS) method to construct the initial sample set. The sampling scheme has the advantage of covering the entire design space and minimizing correlation between the sampled points. I generated a total of 31 sampling points, which exceed the required threshold of \(10n+1\) samples for a valid experimental design, with \(n\) being the number of design variables (in this case, \(n = 3\)). These sampled configurations were then evaluated using the CFD model to obtain the responses.
5.4.2 Kriging-based Surrogate Model
The data points from the experiments and simulations were used to construct the Kriging model. This surrogate model is capable of predicting the outcomes of new design configurations much faster than a full CFD simulation while maintaining high fidelity. To validate the accuracy of the constructed Kriging models, I calculated the coefficient of determination \(R^2\). The value is defined by Eq. (5):
R^2 = 1 – \frac{\sum_{i=1}^{n} (y_i – \hat{y}_i)^2}{\sum_{i=1}^{n} (y_i – \bar{y}_i)^2}
$$
The accuracy of this Kriging model is quite satisfactory, as indicated by the values of \(R^2=0.97\) for the maximum temperature model and \(R^2=0.98\) for the maximum temperature difference model. Both values exceed the typical accuracy threshold of >0.9 for applying the surrogate model in subsequent optimization, confirming the prediction capability of the constructed surrogate model.
5.4.3 NSGA-II Optimization
In the next step, I coupled the approximate Kriging model with the Non-dominated Sorting Genetic Algorithm II (NSGA-II). This algorithm simulates the process of natural selection to explore the design space and identify points on the Pareto frontier. For the surrogate model, the objectives were to minimize the max temperature (to improve cooling performance) and minimize the max temperature difference (to enhance temperature consistency). The NSGA-II parameters were set with a population number of 60, the number of generations equal to 200, with a crossover probability and mutation probability, which are sufficient for this problem to converge to a Pareto optimal front solution.
The generated Pareto front is a set of optimal trade-off solutions among these two objectives. In the optimization procedure, if aiming to minimize the maximum temperature, the algorithm will typically search for a low inlet temperature, larger cold plate depth, and thick PCM, causing a larger temperature difference. If aiming to minimize the temperature difference, larger PCM thickness and higher inlet temperatures are preferentially selected. To select a solution from this Pareto front that best satisfies practical engineering needs and balances two conflicting objectives, I introduced a K-means clustering method. The algorithm automatically groups the Pareto solution sets into clusters based on their distribution. After clustering, the algorithm extracts the cluster center. This identified center represents a trade-off solution in terms of both objectives and was chosen as the final optimal configuration.
The selected optimum configuration obtained from the cluster analysis had a PCM thickness of 3 mm, a cold plate depth of 17 mm, and a cooling liquid inlet temperature of 15 °C. For this final chosen point, the surrogate model predicted a maximum temperature of 35.56 °C and a temperature difference of 2.57 °C. I performed a CFD simulation at this specific configuration to validate the prediction. The comparison between the predicted and verified CFD values is shown in the following table:
| Objective | Prediction | Simulation | Relative error |
|---|---|---|---|
| Maximum temperature (°C) | 35.56 | 35.51 | 0.001 |
| Temperature difference (°C) | 2.57 | 2.43 | 0.058 |
The relative error of the max temperature is less than 0.1%, while the relative error for the max temperature difference is less than 6%. These figures fall within an acceptable engineering tolerance. The numerical analysis evidences the reliability and accuracy of my optimization pipeline. This final solution ensures the battery temperature in the module never exceeds 35.51 °C at a 3C discharge rate while ensuring excellent temperature uniformity (temperature difference under 2.43 °C). The overall thermal performance shows significant improvement compared to the pure-liquid cooling system.
6. Conclusions and Outlook
Focusing on the crucial thermal challenges of lithium-ion traction batteries for electric cars, this work performed a comprehensive study and optimization of a composite cold plate system and phase change material cooling structure. From the results of this thesis, I may draw the following main conclusions:
Based on the Bernardi model, internal resistance experiments were successfully performed to model the heat generation rate. The accurate numerical model of the 21700 cylindrical battery was verified by comparing its temperature fields to experimental data, with a maximum error lower than 2 °C, making the model fully valid for the later pack-level simulations.
In the 2C discharge design, by using an optimization strategy of inserting staggered wedge blocks into the internal fluid channels, I observed a significant increase in local flow disturbance and heat transport. The flow analysis of the streamlines and flow velocity revealed that these structures strongly improve the flow conditions and heat transfer within the channel, leading to an optimized thermal performance of the battery module. A double-sided liquid cooling system further improved the results. The final solution successfully reduced the maximum module temperature to less than 29.84 °C and the maximum temperature difference to less than 4.0 °C at the end of the discharge process.
For the 3C high-rate discharge scenario, a phase change material hybrid cooling system was proposed to improve the battery’s temperature uniformity. The new double-layer liquid cold plate design, integrated into a honeycomb layout, ensures a large cooling area while remaining relatively compact. Single-factor analysis demonstrated that cooling performance is mainly affected by the PCM thickness, the cold plate depth, and the coolant inlet temperature.
In order to get a trade-off design, a multi-objective optimization method was proposed that combines Kriging surrogate modeling and the NSGA-II genetic algorithm. The surrogate models reached high accuracy for both the maximum temperature and the temperature difference values. After clustering the Pareto optimal front, a representative compromise design is found, capable of reducing the battery maximum temperature to only 35.51 °C and keeping the temperature difference as low as 2.43 °C at 3C discharge. The relative error of the optimizer was negligible, proving the strong applicability of my optimization method. The presented comprehensive design strategy and the novel cooling system architecture provide a valuable reference for the broader field of battery thermal management in the context of electric cars.
Future works may consider further research aspects, such as the response of the cooling system to extreme climatic conditions (e.g., sub-zero temperature). For the electric car, the cold plate shape could also be further optimized by topological methods, and different liquid coolants (for example, nanofluids) could be evaluated in the proposed system, leading to additional improvements in both performance and cost-effectiveness.