BYD EV Low-Voltage Power-On Failure Analysis

In my extensive experience with BYD EV models, I have encountered numerous instances where low-voltage power-on failures disrupt the normal operation of these advanced vehicles. As a professional in the field, I find it crucial to delve into the intricacies of the low-voltage power distribution system and the power-on process to effectively diagnose and resolve such issues. The BYD car series, particularly the BYD EV, has gained significant market share due to its affordability and performance, but this popularity also brings to light common faults like low-voltage power-on failures. This article aims to provide a comprehensive analysis of these failures, incorporating detailed explanations, tables, and formulas to enhance understanding. Through a first-person perspective, I will share insights based on practical experiments and real-world cases, emphasizing the importance of systematic troubleshooting for BYD EV owners and technicians.

The low-voltage power distribution system in a BYD EV is a complex network that ensures reliable operation of various electronic components. Primarily, it consists of two key elements: the lead-acid battery and the DC-DC converter. When the BYD car is stationary, the lead-acid battery supplies power to the entire vehicle, supporting functions like lighting and control modules. During operation, the DC-DC converter steps in, transforming high-voltage power from the traction battery into low-voltage electricity to sustain the system. This dual-source setup is critical for maintaining efficiency and safety in BYD EV models. The distribution involves front engine compartment fuse boxes and instrument panel distribution boxes, which house relays and fuses to manage power flow to different modules, such as the battery management system, vehicle control unit, and motor controller. For instance, the front compartment fuse box directs power to high-priority systems, while the instrument panel box handles auxiliary functions like entertainment and lighting. To better illustrate this, consider the following table summarizing the key components and their roles in the BYD EV low-voltage system:

Component Function Voltage Range
Lead-Acid Battery Provides power when vehicle is off or stationary 12V DC
DC-DC Converter Converts high-voltage to low-voltage during operation 12V DC output
Front Compartment Fuse Box Distributes power to control modules (e.g., BMS, VCU) 12V DC
Instrument Panel Distribution Box Manages power to body control modules and accessories 12V DC

Moreover, the low-voltage system in BYD EV vehicles incorporates intelligent features, such as a battery management system that monitors parameters like voltage, current, and temperature. If anomalies are detected, it triggers alerts on the dashboard, prompting users to check the system. This proactive approach helps prevent major failures, but it requires a deep understanding of the underlying principles. For example, the state of charge (SOC) of the battery can be modeled using the formula: $$SOC(t) = SOC_0 – \frac{1}{C} \int_0^t I(\tau) \, d\tau$$ where \( SOC_0 \) is the initial state of charge, \( C \) is the battery capacity, and \( I(\tau) \) is the current over time. This equation highlights how continuous discharge affects the BYD car’s ability to maintain low-voltage power, emphasizing the need for regular maintenance.

Moving on to the low-voltage power-on process in BYD EV models, it involves a sequence of steps that rely on smart key systems and electronic control units. As an expert, I often explain this process to highlight its logic and potential failure points. For keyless entry, the BYD EV uses antennas, micro-switches, and controllers to authenticate the smart key. When a user approaches the left front door and presses the micro-switch, a low-frequency signal (e.g., 125 kHz) is generated and sent to the keyless module. The smart key responds with a high-frequency signal (433 MHz), which is verified by the control unit. Upon successful authentication, the body control module (BCM) activates the door lock motor, allowing entry. This process ensures security but can be prone to issues if signals are interrupted. The power-on sequence follows a similar logic: after entering the BYD car, the driver must press the brake pedal and the start button. The brake signal is transmitted via hardwired connections to the vehicle control unit (VCU), while the start signal communicates through a sub-network to the BCM. The BCM then controls relays, such as the IG3 relay, to supply power to critical modules. If all checks pass, the BYD EV displays an “OK” indicator on the dashboard, signifying successful power-on. To quantify this, the voltage threshold for pre-charging capacitors in the motor controller can be expressed as: $$V_{precharge} = 0.9 \times V_{battery}$$ where \( V_{battery} \) is the high-voltage battery pack voltage (e.g., 400 V), resulting in a pre-charge voltage of approximately 360 V. This step is vital for preventing inrush currents that could damage components in the BYD EV.

In a typical case study of low-voltage power-on failure in a BYD EV, I recall an incident involving a 2021 model that had accumulated around 40,000 kilometers. The owner reported that while keyless entry functioned normally—allowing access to the vehicle—the BYD car failed to power on when the brake pedal was pressed and the start button was activated. The dashboard displayed a “Check Powertrain System” warning, indicating a fault in the low-voltage power-on logic. As part of my analysis, I referred to the BCM circuit diagram to trace the signal flow. The keyless entry worked, implying that the smart key module, power lines, and ground connections were intact. However, the failure during power-on suggested issues with the brake signal or start signal pathways. To diagnose this, I employed a multi-step approach, using tools like a multimeter and a diagnostic scanner. The following table outlines the initial measurements and observations during the fault diagnosis for this BYD EV:

Test Step Measurement Normal Value Observed Value
Battery Voltage Check Voltage at battery terminals 12.0–12.6 V 12.35 V
Fault Code Reading Diagnostic scanner output No codes B1C1607 (Start Button Fault)
Start Button Signal Check Voltage at G16 connector terminals Terminal 1: ~0 V, Terminal 2: ~0 V Terminal 1: 1.45 mV, Terminal 2: 12.01 V

From these results, it was evident that the start button’s terminal 2 had an abnormal voltage, pointing to a potential short circuit. Further investigation involved measuring resistances to isolate the fault. For instance, the resistance between terminal 1 and ground was measured as 1.35 Ω, which deviated from the expected near-zero value for a proper ground. By disconnecting connectors like G21 and G28, I identified a short between the start signal terminal 1 and the brake closed signal terminal 4. This type of fault can be modeled using Ohm’s law: $$R = \frac{V}{I}$$ where an unexpected resistance value indicates insulation breakdown or wiring issues in the BYD EV. In this case, the high resistance suggested corrosion or damage in the wiring harness, common in vehicles with high mileage.

To resolve the fault in this BYD EV, I proceeded with a systematic troubleshooting process. First, I verified the brake signal under different conditions. Without pressing the brake or start button, the voltage at the G21 connector’s terminals 3 and 4 was 0 V, which is normal. When the brake was pressed without activating the start button, both terminals showed 12.15 V, indicating proper signal transmission. However, when both brake and start were engaged, terminal 3 read 12 V, but terminal 4 dropped to 0 V, confirming the short circuit. This inconsistency aligned with the fault code and highlighted the need for repairing the affected wiring. After repairing the shorted connections, I conducted a power-on test: the BYD car started successfully, and the “OK” indicator illuminated, validating the diagnosis. This experience underscores the importance of understanding the low-voltage power-on logic in BYD EV models. For broader application, I often use the following formula to assess voltage drops in such systems: $$\Delta V = I \times R_{wire}$$ where \( \Delta V \) is the voltage drop, \( I \) is the current, and \( R_{wire} \) is the wire resistance. Excessive drops can lead to power-on failures in BYD cars, emphasizing the need for regular inspections.

In conclusion, low-voltage power-on failures in BYD EV vehicles are multifaceted issues that require a methodical approach to diagnosis and repair. Through my first-hand experiences, I have learned that a deep knowledge of the power distribution system and power-on sequence is indispensable. The BYD car’s reliance on electronic control units and signal-based processes means that even minor faults, like shorts in wiring, can cause significant disruptions. By incorporating tools like multimeters and diagnostic scanners, and applying principles such as Ohm’s law, technicians can efficiently pinpoint and resolve these problems. This analysis not only aids in maintaining the reliability of BYD EV models but also contributes to the broader understanding of新能源汽车 technologies. As the adoption of BYD EV cars continues to grow, sharing such detailed case studies will empower users and professionals to tackle similar challenges effectively.