In recent years, the rapid growth of electric vehicles has placed enormous demands on the performance of energy storage systems. Among these, the lithium-ion battery has become the dominant choice for electric vehicle battery packs due to its high energy density, low self-discharge rate, and relatively long cycle life. However, the thermal behavior of the electric vehicle battery is a critical factor that directly affects its safety, reliability, and durability. High operating temperatures or large temperature gradients inside the pack can accelerate capacity fading, reduce round-trip efficiency, and even trigger thermal runaway. Therefore, an effective battery thermal management system is essential for maintaining the electric vehicle battery within an optimum temperature window, typically between 20°C and 40°C, with a small temperature difference between cells.
This thesis presents a comprehensive study on a composite liquid cooling strategy that integrates a liquid cooling plate with a vapor chamber for the thermal management of an electric vehicle battery module. The work begins with a detailed analysis of the heat generation and transfer characteristics of a pouch-type ternary lithium-ion cell. A lumped-parameter thermal model based on the Bernardi heat generation rate is established, and the dynamic internal resistance is experimentally identified through hybrid pulse power characterization. After validating the cell model against constant-current discharge tests, a liquid cooling plate is designed and optimized through an orthogonal experimental approach. The design parameters include channel width, channel height, number of channels, and coolant inlet velocity. A multi-objective evaluation using average temperature, maximum temperature difference, and pressure drop is performed to determine the optimal configuration. To further improve temperature uniformity, a vapor chamber is inserted between the battery and the liquid cooling plate, forming a composite cooling mode. The cooling performance of this composite structure is numerically investigated under different coolant flow rates and inlet temperatures, and the low-temperature preheating capability is also assessed. Finally, an experimental platform is built to validate the numerical results under 2C discharge conditions, and the composite cooling mode is compared with conventional liquid cooling in terms of average temperature and temperature uniformity. The results indicate that the proposed liquid cooling plate–vapor chamber system provides superior thermal management for the electric vehicle battery, especially in terms of reducing maximum temperature difference and maintaining a more uniform temperature distribution.
Thermal Characteristics of the Electric Vehicle Battery
To accurately predict the thermal behavior of the electric vehicle battery, it is necessary to understand its internal structure and heat generation mechanisms. A lithium-ion cell consists of a positive electrode (typically a nickel-cobalt-manganese oxide, NCM), a negative electrode (graphite), a separator, an electrolyte, and current collectors. The cell used in this study is a soft-packed pouch cell with a nominal capacity of 46 Ah and dimensions of 167 mm × 164 mm × 10 mm. The thermodynamic properties of the cell are computed using weighted averages of the constituent materials, as the battery is a composite of multiple layers. The equivalent density, specific heat capacity, and anisotropic thermal conductivities are presented in Table 1.
| Parameter | Value |
|---|---|
| Dimensions (mm) | 167 × 164 × 10 |
| Capacity (Ah) | 46 |
| Density (kg/m³) | 1933 |
| Specific heat capacity (J/(kg·K)) | 1080 |
| In-plane thermal conductivity (W/(m·K)) | 22.3 |
| Through-plane thermal conductivity (W/(m·K)) | 0.66 |
| Positive electrode material | NCM |
| Negative electrode material | Graphite |
| Discharge cutoff voltage (V) | 2.75 |
| Charge cutoff voltage (V) | 4.2 |
The total heat generation inside the battery can be divided into four components: reaction heat, polarization heat, ohmic heat, and side-reaction heat. In normal operation, the side-reaction heat is negligible compared to the other three components. The overall heat generation rate per unit volume is often computed using the well-known Bernardi model, which simplifies the heat generation as the sum of irreversible ohmic heat and reversible entropy change. The expression is given as follows:
$$ q_B = \frac{I}{V_B} \left[ \left( U – U_0 \right) + T_B \frac{\mathrm{d}U}{\mathrm{d}T_B} \right] $$
where \( I \) is the current (A), \( V_B \) is the cell volume (m³), \( U \) is the open-circuit voltage (V), \( U_0 \) is the terminal voltage (V), \( T_B \) is the battery temperature (K), and \( \mathrm{d}U/\mathrm{d}T_B \) is the entropy coefficient, which is often treated as a constant for simplicity. For the present work, the ohmic resistance and the polarization resistance are lumped into a dynamic internal resistance \( R \). Hence, the heat generation rate can be rewritten as:
$$ q_B = \frac{I^2 R}{V_B} + I T_B \frac{\mathrm{d}U}{\mathrm{d}T_B} $$
To determine the dynamic internal resistance, a hybrid pulse power characterization (HPPC) test is conducted at an ambient temperature of 25°C. The cell is first fully charged and then discharged in steps corresponding to a 10% decrease in state of charge (SOC). At each SOC level, a 10-s discharge pulse followed by a 40-s rest and a 10-s charge pulse is applied, and the voltage response is recorded. The ohmic resistance \( R_{\text{ohm}} \) and the polarization resistance \( R_{\text{pol}} \) are calculated from the instantaneous voltage drops and recoveries:
$$ R_{\text{ohm}} = \frac{U_1 – U_2}{I}, \quad R_{\text{pol}} = \frac{U_2 – U_3}{I}, \quad R = R_{\text{ohm}} + R_{\text{pol}} $$
The measured total resistance as a function of SOC is fitted with a fourth-order polynomial, as shown in Table 2. The fitted polynomial is then used as an input to the battery thermal model.
| SOC range | Polynomial expression for R (Ω) |
|---|---|
| 0–1 | \( R = -0.00272\, \mathrm{SOC}^4 + 0.00559\, \mathrm{SOC}^3 – 0.00954\, \mathrm{SOC}^2 + 0.00590\, \mathrm{SOC} + 0.000255 \) |
Using the above parameters, a three-dimensional thermal model of the cell is built in the finite-volume solver. The cell is considered as a homogeneous solid with orthotropic thermal conductivity. The heat generation rate is calculated by a user-defined function based on the fitted resistance. A validation experiment is carried out under a 2C discharge condition in an environment chamber maintained at 25°C. Eight K-type thermocouples are attached to the battery surface to record the temperature distribution. The comparison between the simulated and measured average temperatures shows a maximum relative error of less than 3.5%, which confirms the accuracy of the thermal model. Under natural convection, the average temperature of the cell reaches 46.9°C at the end of the 2C discharge, with a maximum temperature difference of 4.35°C. This result clearly indicates the need for an active cooling system to keep the electric vehicle battery within its preferred operating range.
Design and Optimization of a Liquid Cooling Plate
To efficiently remove heat from the electric vehicle battery, a liquid cooling plate (LCP) is designed to be placed in direct contact with the pouch cell. The LCP is made of aluminum and has the same planar dimensions as the battery, with a wall thickness of 4 mm. A single serpentine channel is routed inside the LCP, and water is used as the coolant. The cooling performance is governed by convective heat transfer in the channel and conductive heat transfer through the plate. The governing equations for the coolant flow and heat transfer are the continuity, momentum, and energy equations:
$$ \nabla \cdot \mathbf{v} = 0 $$
$$ \rho \left( \frac{\partial \mathbf{v}}{\partial t} + \mathbf{v} \cdot \nabla \mathbf{v} \right) = -\nabla p + \mu \nabla^2 \mathbf{v} $$
$$ \rho c_p \left( \frac{\partial T}{\partial t} + \mathbf{v} \cdot \nabla T \right) = \lambda \nabla^2 T $$
where \( \mathbf{v} \) is the velocity vector, \( p \) is pressure, \( \mu \) is dynamic viscosity, \( \rho \) is density, \( c_p \) is specific heat, and \( \lambda \) is thermal conductivity. For the channel dimensions considered here, the Reynolds number is below 2300 for the chosen flow rates, so the flow is laminar.
A CFD model is established using the same geometry and boundary conditions as the experiment. After performing a mesh independence study, a mesh with approximately 224,641 cells is selected, as it gives a good balance between accuracy and computational cost. The grid independence results are summarized in Table 3.
| Number of cells | Average temperature (°C) | Temperature difference (°C) | Pressure drop (Pa) |
|---|---|---|---|
| 33,760 | 32.65 | 2.91 | 7.83 |
| 59,074 | 32.42 | 2.87 | 8.02 |
| 101,978 | 32.21 | 2.85 | 8.11 |
| 184,534 | 32.12 | 2.84 | 8.14 |
| 224,641 | 32.08 | 2.83 | 8.16 |
| 272,100 | 32.07 | 2.83 | 8.16 |
To systematically optimize the LCP geometry, an orthogonal experimental design is employed. Four factors are selected, each with four levels: channel width (A), channel height (B), number of channels (C), and coolant inlet velocity (D). The factors and levels are listed in Table 4.
| Level | A (mm) | B (mm) | C (rows) | D (m/s) |
|---|---|---|---|---|
| 1 | 9 | 5 | 4 | 0.01 |
| 2 | 11 | 6 | 5 | 0.02 |
| 3 | 13 | 7 | 6 | 0.03 |
| 4 | 15 | 8 | 7 | 0.04 |
An \( L_{16}(4^4) \) orthogonal array is utilized. For each combination, the CFD simulation is performed under 2C discharge conditions with an ambient and coolant temperature of 25°C. The evaluation indicators are the average temperature of the battery, the maximum temperature difference, and the pressure drop through the LCP. The results of the 16 simulations are shown in Table 5.
| No. | A (mm) | B (mm) | C (rows) | D (m/s) | T_avg (°C) | ΔT (°C) | ΔP (Pa) |
|---|---|---|---|---|---|---|---|
| 1 | 9 | 5 | 4 | 0.01 | 35.60 | 2.44 | 3.07 |
| 2 | 9 | 6 | 5 | 0.02 | 33.74 | 2.91 | 5.72 |
| 3 | 9 | 7 | 6 | 0.03 | 32.52 | 2.73 | 8.70 |
| 4 | 9 | 8 | 7 | 0.04 | 31.92 | 2.70 | 10.84 |
| 5 | 11 | 5 | 7 | 0.02 | 33.78 | 2.74 | 7.56 |
| 6 | 11 | 6 | 6 | 0.01 | 35.33 | 2.63 | 2.21 |
| 7 | 11 | 7 | 5 | 0.04 | 31.94 | 2.78 | 8.99 |
| 8 | 11 | 8 | 4 | 0.03 | 32.62 | 2.56 | 5.10 |
| 9 | 13 | 5 | 5 | 0.03 | 32.67 | 2.81 | 8.55 |
| 10 | 13 | 6 | 4 | 0.04 | 31.98 | 2.68 | 8.63 |
| 11 | 13 | 7 | 7 | 0.01 | 35.07 | 2.46 | 1.64 |
| 12 | 13 | 8 | 6 | 0.02 | 33.54 | 2.80 | 3.08 |
| 13 | 15 | 5 | 6 | 0.04 | 31.98 | 2.78 | 11.55 |
| 14 | 15 | 6 | 7 | 0.03 | 32.60 | 2.90 | 6.73 |
| 15 | 15 | 7 | 4 | 0.02 | 33.65 | 2.78 | 2.84 |
| 16 | 15 | 8 | 5 | 0.01 | 34.97 | 2.54 | 1.18 |
Range analysis and standard deviation analysis are performed to determine the significance of each factor. The average value \( K_{in} \) for the \( i \)-th factor at the \( n \)-th level is computed, and the range \( R_i \) is obtained as the difference between the maximum and minimum \( K_{in} \). The standard deviation \( S_i \) is also calculated to evaluate the influence of each factor on the indicators. Tables 6 and 7 present the range analysis results for average temperature and temperature difference, respectively.
| Factor | K1 | K2 | K3 | K4 | R | S |
|---|---|---|---|---|---|---|
| A | 33.45 | 33.42 | 33.31 | 33.30 | 0.150 | 0.065 |
| B | 33.51 | 33.41 | 33.29 | 33.26 | 0.244 | 0.097 |
| C | 33.46 | 33.33 | 33.34 | 33.34 | 0.136 | 0.055 |
| D | 35.24 | 33.68 | 32.60 | 31.95 | 3.288 | 1.245 |
| Factor | K1 | K2 | K3 | K4 | R | S |
|---|---|---|---|---|---|---|
| A | 2.69 | 2.63 | 2.69 | 2.75 | 0.123 | 0.044 |
| B | 2.69 | 2.73 | 2.69 | 2.65 | 0.078 | 0.028 |
| C | 2.62 | 2.76 | 2.68 | 2.70 | 0.142 | 0.051 |
| D | 2.47 | 2.81 | 2.75 | 2.73 | 0.336 | 0.130 |
The results reveal that the coolant inlet velocity (factor D) is the dominant factor for both the average temperature and the temperature difference. For the average temperature, the influence order is D > B > A > C. For the temperature difference, the influence order is D > C > A > B. Although a lower flow rate reduces the temperature difference, it significantly increases the average temperature. Therefore, a compromise is required. Considering the overall performance and the fact that all pressure drops are within an acceptable range, the optimal combination is selected as A4, B4, C4, D4, i.e., a channel width of 15 mm, a channel height of 8 mm, seven channels, and a coolant velocity of 0.04 m/s. This optimized LCP model yields an average battery temperature of 31.89°C and a maximum temperature difference of 2.88°C at the end of the 2C discharge. The optimized LCP reduces the average temperature by 3.71°C compared to the worst orthogonal case, but the temperature difference still remains above 2.8°C, indicating that further improvement in temperature uniformity is required.
Composite Liquid Cooling Structure with Vapor Chamber
To enhance the temperature uniformity of the electric vehicle battery, a vapor chamber (VC) is introduced between the battery and the optimized LCP. The VC acts as a highly conductive heat spreader that effectively flattens the temperature gradient on the battery surface. In the numerical model, the VC is treated as a solid block with an equivalent thermal conductivity of 5000 W/(m·K), which represents the two-phase heat transfer behavior of the VC. The composite cooling mode is denoted LCP-VC, while the conventional liquid cooling mode is denoted LCP. A comparison of the temperature fields for a single cell is shown in Table 8.
| Cooling mode | Average temperature (°C) | Maximum temperature (°C) | Temperature difference (°C) |
|---|---|---|---|
| LCP | 31.89 | 32.82 | 2.86 |
| LCP-VC | 32.06 | 32.65 | 1.42 |
Although the average temperature is slightly higher in the LCP-VC mode due to the additional thermal resistance of the VC, the maximum temperature is reduced by 0.17°C and the temperature difference is reduced by 50.3% (from 2.86°C to 1.42°C). This indicates that the VC significantly improves the thermal uniformity of the electric vehicle battery without sacrificing cooling capacity.
To examine the scalability of the proposed cooling concept, three module-level configurations are designed and evaluated. Case1 consists of three cells, Case2 contains six cells, and Case3 contains nine cells. In each configuration, the cells, VCs, and LCPs are stacked alternately. The cooling performance is evaluated under 2C discharge conditions at 25°C ambient and coolant temperature, with a coolant velocity of 0.04 m/s. Table 9 summarizes the average temperature, maximum temperature difference, and maximum temperature for each configuration in both LCP and LCP-VC modes.
| Configuration | Mode | T_avg (°C) | ΔT (°C) | T_max (°C) |
|---|---|---|---|---|
| Case1 (3 cells) | LCP | 31.67 | 6.98 | 35.72 |
| Case1 (3 cells) | LCP-VC | 31.90 | 5.85 | 35.52 |
| Case2 (6 cells) | LCP | 33.90 | 7.88 | 38.82 |
| Case2 (6 cells) | LCP-VC | 33.23 | 2.42 | 35.04 |
| Case3 (9 cells) | LCP | 36.03 | 9.32 | 39.34 |
| Case3 (9 cells) | LCP-VC | 36.41 | 4.16 | 38.80 |
For all configurations, the LCP-VC mode produces a much lower temperature difference than the LCP mode. The improvement is particularly significant in Case2 and Case3, where the temperature difference decreases from 7.88°C to 2.42°C and from 9.32°C to 4.16°C, respectively. In addition, the maximum temperature in the LCP-VC mode is always lower than that in the LCP mode. These results demonstrate that the composite cooling structure is effective at the module level and can keep the electric vehicle battery within the desired temperature range even for a nine-cell module.

The effect of coolant flow rate on the cooling performance of the electric vehicle battery module is investigated for both cooling modes. The coolant inlet temperature is held at 25°C, and four flow rates are tested: 0.01, 0.02, 0.03, and 0.04 m/s. The results are presented in Table 10 for the Case2 module. As the flow rate increases, the average temperature generally decreases, but the temperature difference tends to increase. The LCP-VC mode maintains a consistently lower temperature difference compared to the LCP mode. The best overall thermal performance is observed at 0.04 m/s for the LCP-VC mode, where the average temperature is 33.23°C and the temperature difference is only 2.42°C.
| Velocity (m/s) | LCP T_avg (°C) | LCP ΔT (°C) | LCP-VC T_avg (°C) | LCP-VC ΔT (°C) |
|---|---|---|---|---|
| 0.01 | 35.26 | 3.63 | 34.93 | 2.28 |
| 0.02 | 34.51 | 4.02 | 34.22 | 2.35 |
| 0.03 | 33.98 | 4.15 | 33.61 | 2.40 |
| 0.04 | 33.58 | 4.23 | 33.23 | 2.42 |
The coolant inlet temperature also has a strong influence on the thermal management of the electric vehicle battery. Simulations are performed with coolant temperatures of 15, 20, 25, and 30°C at a fixed flow rate of 0.04 m/s. Table 11 shows the resulting average temperature and temperature difference for a single cell. The LCP-VC mode consistently yields a lower maximum temperature and a much lower temperature difference than the LCP mode across all inlet temperatures. The advantage becomes more pronounced when the coolant temperature is lower, because the VC helps to distribute the cooled region more evenly over the battery surface.
| Inlet temp (°C) | LCP T_max (°C) | LCP ΔT (°C) | LCP-VC T_max (°C) | LCP-VC ΔT (°C) |
|---|---|---|---|---|
| 15 | 31.24 | 9.22 | 30.38 | 4.33 |
| 20 | 34.92 | 8.64 | 33.97 | 4.18 |
| 25 | 38.60 | 8.10 | 37.60 | 4.05 |
| 30 | 43.40 | 7.96 | 42.06 | 4.11 |
Low-temperature preheating is another important function of a battery thermal management system, especially for an electric vehicle battery operating in cold climates. In this study, the preheating performance of the LCP-VC mode is simulated at an initial battery and ambient temperature of −10°C, with heating medium temperatures of 15, 20, 25, and 30°C and a flow rate of 0.4 m/s. The time required to heat the battery average temperature from −10°C to 10°C is listed in Table 12. The LCP-VC mode reduces the heating time by approximately 10% compared to the LCP mode. In addition, the temperature difference inside the module is reduced by about 12% when the VC is used. Thus, the composite structure not only improves cooling performance but also enhances low-temperature heating uniformity.
| Medium temp (°C) | LCP heating time (s) | LCP-VC heating time (s) |
|---|---|---|
| 15 | 378 | 362 |
| 20 | 258 | 241 |
| 25 | 212 | 193 |
| 30 | 184 | 165 |
Experimental Validation and Discussion
An experimental test bench is constructed to validate the numerical results obtained for the composite cooling structure. The test bench consists of a battery tester, a temperature data acquisition unit, a peristaltic pump, a constant-temperature water bath, an environmental chamber, and the cooling components. The same soft-packed cell is used, and a thermocouple arrangement is adopted to measure the surface temperature at multiple locations. The experimental procedure includes fully charging the cell at 1C, then resting it in the chamber at 25°C until thermal equilibrium is reached. The cell is discharged at 2C while the coolant flows through the LCP at a prescribed velocity. Two cooling modes are tested: LCP alone and LCP-VC. The measured temperature profiles are compared with simulation predictions.
Table 13 shows the final average temperatures and maximum temperature differences for both modes at a coolant velocity of 0.04 m/s and a coolant/environment temperature of 25°C. The experimental average temperature for the LCP-VC mode is 35.13°C, which is 0.82°C lower than that of the LCP mode (35.95°C). The maximum temperature difference is 3.69°C for LCP-VC and 3.98°C for LCP, corresponding to a 7.2% improvement in temperature uniformity. The trends observed in the experiments are consistent with the simulations, although the absolute temperature values are higher in the experiments due to contact thermal resistance, imperfect insulation, and heat losses to the environment.
| Cooling mode | T_avg experiment (°C) | ΔT experiment (°C) | T_avg simulation (°C) | ΔT simulation (°C) |
|---|---|---|---|---|
| NC | 46.68 | 3.27 | 46.92 | 0.76 |
| LCP | 35.95 | 3.98 | 31.89 | 2.88 |
| LCP-VC | 35.13 | 3.69 | 32.06 | 1.42 |
To further investigate the influence of coolant flow rate, experiments are carried out at 0.01, 0.02, 0.03, and 0.04 m/s. Figure 1, inserted earlier, illustrates a typical electric vehicle battery pack in service. The measured average temperature and temperature difference for both cooling modes are summarized in Table 14. In all tested cases, the LCP-VC mode yields a lower average temperature and a lower temperature difference compared to the LCP mode. The difference in average temperature between the two modes is more pronounced at higher flow rates, while the advantage in temperature uniformity remains consistent.
| Velocity (m/s) | LCP T_avg (°C) | LCP ΔT (°C) | LCP-VC T_avg (°C) | LCP-VC ΔT (°C) |
|---|---|---|---|---|
| 0.01 | 38.23 | 3.20 | 37.86 | 2.53 |
| 0.02 | 36.84 | 3.22 | 36.41 | 2.41 |
| 0.03 | 36.30 | 3.74 | 35.72 | 3.05 |
| 0.04 | 35.95 | 3.98 | 35.13 | 3.69 |
The experimental results confirm that the composite liquid cooling system with an embedded vapor chamber is an effective solution for the thermal management of an electric vehicle battery. The VC improves the lateral heat spreading and reduces the hot-spot temperature, thereby enabling a more uniform temperature distribution on the battery surface. This is particularly beneficial for high-rate discharge operations, where the heat generation is intense and the temperature gradient tends to be large.
Conclusion
This thesis presents a comprehensive investigation of a composite liquid cooling architecture for the thermal management of an electric vehicle battery. A validated thermal model of a 46 Ah pouch cell is established, and an optimized liquid cooling plate is designed using an orthogonal experimental method. The addition of a vapor chamber to the liquid cooling plate significantly improves temperature uniformity without compromising the cooling capacity. Simulation results show that the LCP-VC mode reduces the maximum temperature difference from 2.88°C to 1.42°C for a single cell, and from 7.88°C to 2.42°C for a six-cell module. The composite structure also provides faster and more uniform heating at low ambient temperatures. Experimental validation under 2C discharge conditions confirms the numerical trends, with the LCP-VC mode achieving an average temperature of 35.13°C and a maximum temperature difference of 3.69°C, outperforming the conventional liquid cooling mode. The proposed composite cooling system offers a practical and efficient approach for maintaining the electric vehicle battery within its optimal operating temperature window, thus enhancing the safety, performance, and lifespan of electric vehicle battery packs.