Liquid-Cooled Thermal Management for Cylindrical EV Battery Packs

1. Introduction and Research Motivation

The rapid expansion of electric mobility has made the EV battery one of the most important components in modern vehicle engineering. In many countries, the electrification of road transport is considered a core strategy for reducing greenhouse gas emissions and petroleum dependence. As a result, EV battery systems are now designed with increasingly higher energy densities and faster charging capability. However, the high energy density that enables long driving range also creates a serious challenge from the thermal point of view. During charge and discharge, the lithium-ion cells inside an EV battery pack release heat because of electrochemical reactions, ohmic losses, and polarization processes. When cells are packaged closely together to save space, heat is not easily removed and the core temperature of the pack can rise rapidly.

Temperature affects almost every performance metric of a lithium-ion battery. If the cell temperature becomes too high, cathode degradation, electrolyte decomposition, and separator shrinkage may be accelerated. If the temperature is too low, lithium plating and electrolyte freezing can occur. In addition to absolute temperature, temperature non-uniformity inside the pack is also critical. If some cells are significantly hotter than their neighbors, those cells age faster and produce less capacity than the rest of the pack. This imbalance reduces the usable energy of the whole EV battery and may eventually trigger overheating and thermal runaway. Therefore, an effective EV battery thermal management system must satisfy three requirements: maintain the pack temperature within a safe operating range, limit the maximum temperature difference among cells, and do so with acceptable parasitic energy consumption.

The scientific literature describes several cooling methods for lithium-ion battery packs. Air-cooling systems are simple, light, and inexpensive, but their heat transfer coefficient is low because air has a small specific heat capacity and thermal conductivity. Liquid cooling systems use a cold plate or tube in contact with the cells, and water-glycol mixtures flow through the plate to carry heat away. Liquid cooling has much better convective heat transfer performance than air cooling and is widely used in commercial EV battery packs. Phase-change-material cooling can absorb a large amount of heat during melting and provides excellent temperature uniformity, but it adds mass and complexity and is still under development for large-scale automotive use.

In this work, I studied a 21700 cylindrical lithium-ion cell and a compact liquid-cooled battery module. The research approach combines theoretical analysis, experimental characterization, and computational fluid dynamics simulations. The aims were to understand the thermal behavior of the cell, to compare different liquid-cooled plate layouts, and to propose a gradient cold plate design that solves the common problem of temperature rising along the coolant flow direction. A large portion of the work is therefore directed toward EV battery pack geometry optimization, cooling fluid selection, and validation of a numerical thermal model with laboratory tests.

2. Thermal Theory and Properties of the Lithium-Ion Cell

2.1 Cell construction and working principle

The cell studied in this paper is a cylindrical 21700 lithium-ion cell with a diameter of 21 mm, height of 70 mm, nominal capacity of 4.0 Ah, nominal voltage of 3.65 V, charge cutoff voltage of 4.2 V, and discharge cutoff voltage of 2.75 V. The main components are the positive electrode, negative electrode, electrolyte, separator, current collectors, and a metal housing. The positive electrode is made from a nickel-cobalt-manganese oxide ternary material. During charging, lithium ions are extracted from the positive electrode and moved through the electrolyte and separator into the negative graphite structure. During discharging, lithium ions leave the negative electrode and return to the positive electrode. Electrons travel around the external circuit to provide electric power.

The electrode reactions can be represented, conceptually, by the following reversible equations. For a transition-metal oxide cathode with M representing a combination of Ni, Co, and Mn,

$$
\mathrm{Li}M\mathrm{O}_{2} \rightleftharpoons \mathrm{Li}_{1-x}M\mathrm{O}_{2} + x\mathrm{Li}^{+} + x e^{-}
$$

while the negative electrode reaction is

$$
\mathrm{C}_{6} + x\mathrm{Li}^{+} + x e^{-} \rightleftharpoons \mathrm{Li}_{x}\mathrm{C}_{6}
$$

Charging moves the equations in the direction that stores lithium in the graphite; discharging reverses the direction and delivers current to the vehicle.

2.2 Heat generation and heat transfer

Heat generation inside a lithium-ion cell is the sum of several contributions:

$$
Q_{\mathrm{total}} = Q_{\mathrm{reaction}} + Q_{\mathrm{ohmic}} + Q_{\mathrm{polarization}} + Q_{\mathrm{side}}
$$

Here, \(Q_{\mathrm{reaction}}\) is the reversible electrochemical reaction heat, \(Q_{\mathrm{ohmic}}\) is the heat produced by ohmic resistance, \(Q_{\mathrm{polarization}}\) is heat generated by polarization resistance, and \(Q_{\mathrm{side}}\) represents side-reaction heat. The reversible heat can be written as

$$
Q_{\mathrm{reaction}} = \frac{n m_e I}{M F}
$$

where \(n\) is the number of cells, \(m_e\) is the active electrode mass, \(I\) is current, \(M\) is molar mass, and \(F\) is the Faraday constant. The ohmic term is

$$
Q_{\mathrm{ohmic}} = I^{2} R_{0}
$$

and the polarization term is

$$
Q_{\mathrm{polarization}} = I^{2} R_{p}
$$

where \(R_{0}\) and \(R_{p}\) are the ohmic and polarization resistances, respectively. Because side reactions are negligible under normal operation, they are usually omitted from the thermal model.

Heat is removed from a battery by three fundamental modes: conduction, convection, and radiation. Conduction inside the cell follows Fourier’s law,

$$
q = -\lambda \frac{\partial T}{\partial x}
$$

Convective heat transfer at the cell surface follows Newton’s law of cooling,

$$
Q_{\mathrm{conv}} = h A \Delta T
$$

and radiation follows the Stefan–Boltzmann equation,

$$
Q_{\mathrm{rad}} = \varepsilon \sigma A T^{4}
$$

For an EV battery module, thermal conduction through active materials is normally the dominant pathway inside the cell, while forced convection by coolant determines the cooling rate at the surface.

2.3 Equivalent thermophysical properties

Since a lithium-ion cell is a multilayer composite, it is impractical to model every layer separately in a pack-level simulation. Instead, equivalent thermophysical properties were calculated. The equivalent density is

$$
\rho = \frac{m}{V} = \frac{\sum m_i}{\sum V_i}
$$

The equivalent specific heat capacity is obtained by mass averaging:

$$
C_{p} = \frac{1}{m} \sum_{i} m_i c_{p,i}
$$

The equivalent thermal conductivities are obtained from series and parallel models of the layered electrodes and separator. The resulting properties are listed in Table 2.1.

Table 2.1 Equivalent thermal properties of the 21700 ternary lithium-ion cell
Property Value
Density / kg m-3 2846
Specific heat capacity / J kg-1 K-1 1327
Thermal conductivity, radial / W m-1 K-1 2.7
Thermal conductivity, circumferential / W m-1 K-1 2.7
Thermal conductivity, axial / W m-1 K-1 29.0

3. Single-Cell Experiments and Model Validation

3.1 Test platform and HPPC resistance measurement

To obtain accurate heat-source data, I built a cell test platform consisting of a battery test system, a constant-temperature environmental chamber, thermocouples, and a data acquisition unit. The test system was used to charge and discharge the 21700 cell under controlled current profiles. Internal resistance was measured with the Hybrid Pulse Power Characteristic method. In this method, a short discharge current pulse is applied to the cell, followed by a rest period and a charge pulse. The voltage responses are used to compute the ohmic resistance and the polarization resistance.

$$
R_{0} = \frac{U_{0} – U_{1}}{I}, \qquad R_{p} = \frac{U_{1} – U_{2}}{I}, \qquad R_{\mathrm{total}} = R_{0} + R_{p}
$$

These resistance values are important because they determine the \(I^{2}R\) heat loss in the cell at a given state-of-charge and temperature.

I measured the resistance at environmental temperatures of 0 °C, 5 °C, 15 °C, 25 °C, and 35 °C, and at states of charge of 90%, 80%, 70%, 60%, 50%, 40%, 30%, 20%, and 10%. The discharge rate was varied among 0.5C, 1C, and 2C. In general, the internal resistance decreased as temperature increased because higher temperature improves electrolyte conductivity and electrochemical kinetics. The internal resistance also increased when SOC fell below roughly 40%, and the rise became especially sharp near the end of discharge. Table 3.1 gives the measured total internal resistance at 2C discharge.

Table 3.1 Internal resistance of the cell at 2C discharge for different temperatures and SOC values / Ω
SOC 90% 80% 70% 60% 50% 40% 30% 20% 10%
0 °C 0.0948 0.0873 0.0886 0.0893 0.0896 0.0925 0.0997 0.1066 0.1339
5 °C 0.0760 0.0765 0.0768 0.0757 0.0748 0.0757 0.0780 0.0834 0.0878
15 °C 0.0589 0.0605 0.0605 0.0622 0.0576 0.0564 0.0569 0.0649 0.0819
25 °C 0.0397 0.0402 0.0406 0.0396 0.0385 0.0392 0.0408 0.0448 0.0639
35 °C 0.0382 0.0388 0.0399 0.0395 0.0382 0.0380 0.0389 0.0405 0.0487

3.2 Temperature-rise characterization

The cell temperature-rise tests were performed in an ambient temperature of 25 °C. Discharge rates of 0.5C, 1C, 1.5C, and 2C were selected. Surface temperatures were measured near the positive electrode, negative electrode, and middle of the cell using thermocouples. The three readings were averaged to represent the mean surface temperature. At 0.5C, the temperature rose slowly and stabilized around 27.5 °C. At 1C, the temperature reached about 29.5 °C. At 2C, the cell surface temperature exceeded 35 °C. These experiments show that higher discharge rates generate more heat and lead to a larger temperature rise. Therefore, an EV battery operating at high discharge rates demands a more aggressive thermal management strategy.

3.3 Thermal model and heat-source function

For the numerical model, the cell was assumed to be a homogeneous anisotropic solid with equivalent thermal properties. Conduction inside the cell is described by

$$
\rho C_{p}\frac{\partial T}{\partial t} = \lambda_{r}\frac{\partial^{2}T}{\partial r^{2}} + \frac{\lambda_{r}}{r}\frac{\partial T}{\partial r} + \lambda_{z}\frac{\partial^{2}T}{\partial z^{2}} + q_{\mathrm{gen}}
$$

In cylindrical coordinates, \(\lambda_{r}\) is the radial conductivity and \(\lambda_{z}\) is the axial conductivity. The volumetric heat source \(q_{\mathrm{gen}}\) was defined with the Bernardi energy balance:

$$
q_{\mathrm{gen}} = \frac{1}{V_{\mathrm{cell}}} \left[ I^{2} R_{\mathrm{int}} + I T \frac{\partial U_{\mathrm{ocv}}}{\partial T} \right]
$$

Because \(R_{\mathrm{int}}\) depends on SOC, I converted discharge time into SOC by the constant-current relation:

$$
\mathrm{SOC} = \mathrm{SOC}_{0} – \frac{I t}{3600 C_{\mathrm{cap}}}
$$

Then, resistance was expressed as a sixth-order polynomial of SOC. For example, at 2C discharge,

$$
R_{\mathrm{int}}(s) = 17.3s^{6} – 57.14s^{5} + 75.33s^{4} – 51s^{3} + 18.53s^{2} – 3.444s + 0.297
$$

where \(s\) is the fractional state of charge. Similar polynomial expressions were obtained for 0.5C, 1C, and 1.5C. These expressions were written into a user-defined function in Fluent and activated as a volumetric heat source in each cell zone.

3.4 Simulation setup and validation

The 3D cell model was meshed with a poly-hexcore method. The energy equation was solved with a pressure-based transient solver. The outer boundaries of the cell were treated as natural-convection walls with a heat transfer coefficient of \(5\ \mathrm{W\ m^{-2}\ K^{-1}}\). The emissivity of the surface was set to 0.2. The initial cell temperature was 25 °C. The time step was set at 1 s, and the energy residual was set to \(10^{-6}\). Simulations were run at the same discharge rates as the tests.

When the simulated surface temperature was compared with the measured surface temperature, the maximum deviation was below 3% for the different discharge rates. This good agreement confirms that the heat-source model and equivalent thermal properties are sufficiently accurate. The validated cell-level model was then used as the foundation for the module-level cooling study.

4. Liquid-Cooled EV Battery Pack Design

4.1 Air-cooling baseline

Before designing the liquid cooling system, I simulated an air-cooled case as a reference. A forced airflow of \(5\ \mathrm{m/s}\) was directed through the battery module while the cells discharged at 2C in a 25 °C environment. The simulation predicted a maximum battery temperature of 42.7 °C and a maximum temperature difference of 11.77 °C. This temperature difference is much larger than the commonly recommended 5 °C limit for EV battery modules. Therefore, air cooling alone is insufficient for this high-rate discharge condition.

4.2 Liquid-cooling scheme and materials

I selected an indirect liquid-cooling method. In this arrangement, coolant flows through channels embedded in a cold plate, and the cold plate is attached to the cylindrical cells with thermal interface material. This avoids direct contact between the conductive cell surface and the liquid, and the arrangement can nevertheless achieve high heat-transfer rates. A 50% ethylene-glycol-water solution was used as the coolant. The cold plate was modelled as aluminum alloy 6063, while a thermal silicone pad was inserted between the cells and the cold plate to reduce contact resistance. The thermal properties used in the CFD model are listed in Table 4.1.

Table 4.1 Thermophysical properties of the cooling-system materials
Material Density / kg m-3 Specific heat / J kg-1 K-1 Thermal conductivity / W m-1 K-1
Thermal silicone 1700 1360 2.0
Water-ethylene-glycol 50% 1082 3300 0.4
Aluminum alloy 6063 2690 900 218

The battery pack model contained 48 cylindrical cells. The cold plate was shaped as a semi-circular arc to conform to the outer circumference of the 21700 cells. A thin layer of thermal silicone, 0.25 mm thick, was placed between each cell and the cold plate. By using an arc-shaped contact surface, the effective heat-exchange area is larger than that of a flat plate, and the heat from the cylindrical cell can be conducted more effectively into the cooling channel.

Eight configurations were designed. Four base layouts were considered: an S-shaped series flow channel, a U-shaped parallel flow channel, a Z-shaped parallel flow channel, and a center-fed “Zhong-shaped” parallel channel. Each layout was implemented with both a single passage and a dual-passage variant. Thus, the configurations were numbered as follows:

  • Structure I: S-shaped series, single channel
  • Structure II: S-shaped series, dual channel
  • Structure III: U-shaped parallel, single channel
  • Structure IV: U-shaped parallel, dual channel
  • Structure V: Z-shaped parallel, single channel
  • Structure VI: Z-shaped parallel, dual channel
  • Structure VII: Zhong-shaped center-fed, single channel
  • Structure VIII: Zhong-shaped center-fed, dual channel

The model width of the cold plate was 26.5 mm. For single-channel cases, the channel height was 48 mm and the width was 3 mm. For dual-channel cases, each channel had a height of 23.5 mm and a width of 3 mm. The battery spacing was 5.5 mm along one direction and 4.5 mm along the other.

4.3 Numerical model and boundary conditions

The cooled module was meshed in ANSYS Meshing using the poly-hexcore method. The liquid domain was captured with boundary-layer inflation to resolve velocity and temperature gradients near the channel walls. A grid-independence check was performed by increasing mesh density until the maximum temperature changed by less than 0.03% and the pressure drop changed by less than 0.8%. The final mesh had about 3.94 million cells. The same grid-convergence approach was applied to all eight configurations.

In the simulation, the inlet coolant velocity was initially set to \(0.5\ \mathrm{m/s}\), the coolant inlet temperature was 25 °C, and the ambient temperature was 25 °C. The outlet was assigned a pressure-outlet boundary condition. The external walls of the batteries and cooling plate were exposed to natural convection with a coefficient of \(5\ \mathrm{W\ m^{-2}\ K^{-1}}\). For the liquid-cooling simulations, the Realizable \(k\)-\(\varepsilon\) turbulence model was selected because the Reynolds number in the representative channel exceeded 4000.

4.4 Comparison of the eight cooling structures

Table 4.2 summarizes the simulated minimum temperature, maximum temperature, and maximum temperature difference of the battery pack after completing a 2C discharge. The lowest maximum temperature of 31.45 °C was obtained by Structure II. This structure also produced the smallest maximum temperature difference of 5.81 °C. Structures with double channels consistently reduced the temperature difference relative to their single-channel counterparts, but the improvement was small, approximately 0.1–0.3 °C. The largest maximum temperature was 32.85 °C in Structure IV, while the largest temperature difference was 7.42 °C in Structure III.

Table 4.2 Battery pack temperature results for eight liquid-cooled plate structures
Configuration Minimum temperature / °C Maximum temperature / °C Temperature difference / °C
Structure I 25.52 31.63 6.11
Structure II 25.64 31.45 5.81
Structure III 25.35 32.77 7.42
Structure IV 25.56 32.85 7.29
Structure V 25.37 31.93 6.56
Structure VI 25.45 31.85 6.40
Structure VII 25.42 31.81 6.39
Structure VIII 25.48 31.78 6.30

Although the dual-channel S-shaped structure provided the best temperature distribution, it also produced the highest coolant pressure drop. Table 4.3 lists the fluid-domain pressure drop for each configuration. The long series flow path in Structures I and II caused pressure drops of 4636.74 Pa and 4888.04 Pa, respectively, while the parallel structures, especially Structures VII and VIII, reduced the pressure drop to less than 1000 Pa. In an EV battery thermal-management system, high pressure drop means high pump power and greater energy loss. Therefore, the flow-path choice must balance cooling performance with pumping cost.

Table 4.3 Fluid pressure drop for each configuration
Configuration Minimum pressure / Pa Maximum pressure / Pa Pressure drop / Pa
Structure I 0.77 4637.51 4636.74
Structure II 1.00 4889.04 4888.04
Structure III 1.25 994.41 993.16
Structure IV 1.18 1028.29 1027.11
Structure V 1.19 1136.61 1135.42
Structure VI 1.23 1177.76 1176.53
Structure VII -44.50 870.66 915.16
Structure VIII -41.99 902.83 944.82

Considering both temperature and pressure drop, Structure II still offered the best compromise for further study because the maximum temperature and the maximum temperature difference were both the smallest among all configurations. Although its pressure drop was high, this can be reduced by adjusting the coolant flow rate and plate height. As discussed below, such parameter adjustments make Structure II attractive for achieving the temperature-uniformity target.

4.5 Influence of coolant velocity, inlet temperature, and plate height

4.5.1 Coolant inlet velocity

I simulated Structure II for coolant inlet velocities of 0.05, 0.1, 0.2, 0.3, 0.4, and 0.5 m/s. Increasing the velocity improves the heat transfer coefficient and lowers the battery maximum temperature. However, the improvement is not linear. When the velocity was raised from 0.3 to 0.4 m/s, the maximum temperature and temperature difference decreased by only 0.25 °C and 0.09 °C, respectively. This means that after a certain velocity, the cooling effect approaches an asymptote. At the same time, the pressure drop grows rapidly with velocity. When the velocity changed from 0.3 to 0.4 m/s, the pressure drop increased by 1.18 kPa. Consequently, a coolant velocity around 0.3 m/s appears reasonable for Structure II because it gives strong cooling without excessive pumping loss.

4.5.2 Coolant inlet temperature

The coolant inlet temperature determines the baseline from which the battery is cooled. I set the coolant velocity to 0.3 m/s and the ambient temperature to 25 °C, and evaluated inlet temperatures of 15, 20, 25, and 30 °C. The results are given in Table 4.4. A low coolant inlet temperature is effective at suppressing the maximum temperature, but it increases the maximum temperature difference because the cells near the inlet are cooled much more strongly than cells near the outlet. This trade-off must be considered when designing an EV battery cooling circuit.

Table 4.4 Effect of coolant inlet temperature on battery pack temperature
Coolant inlet temperature / °C Battery maximum temperature / °C Maximum temperature difference / °C
15 22.42 6.47
20 27.13 6.21
25 31.85 5.96
30 36.56 5.70

4.5.3 Liquid cold plate height

The height of the semi-circular cold plate controls the contact area between the cold plate and the cylindrical cells. I investigated plate heights of 50, 55, 60, and 65 mm. Raising the plate height from 50 to 65 mm reduced the maximum temperature by 1.24 °C, then 1.15 °C, and then 0.75 °C. The temperature difference also fell by 0.98 °C, 1.16 °C, and then 0.76 °C. With a height of 55 mm, a coolant velocity of 0.3 m/s, and an inlet temperature of 25 °C, the battery maximum temperature was 30.61 °C and the maximum temperature difference remained below 5 °C. This combination satisfies the normal EV battery operation target while limiting additional plate mass and manufacturing cost.

5. Gradient Liquid-Cooled Battery Module

5.1 Problem statement and module design

The temperature contours of the eight liquid-cooled configurations revealed a common issue: cell temperature tends to increase monotonically along the coolant-flow direction. The coolant becomes warmer as it absorbs heat from each cell, so downstream cells are always exposed to a warmer fluid. This leads to a temperature gradient through the module and restricts the thermal uniformity of the EV battery pack.

To address this issue, I proposed a gradient cold-plate structure in which the height of the cooling plate increases stepwise along the flow direction. Because coolant temperature rises as it moves downstream, the heat-transfer area is increased downstream to compensate for the higher coolant temperature. This design gives a more uniform surface temperature over the whole battery module.

To make the experimental system easier to build and the numerical model easier to validate, the 48-cell battery pack was simplified to an 18-cell module. The module contains a single row of nine cells on each side of the central cold plate. The cells are divided into three groups, and each group has a different cold-plate height. The initial cold plate heights are 55 mm, 60 mm, and 65 mm for the first, middle, and last groups, respectively. The cold plate length is 233.5 mm, and the main channel height is 50 mm. Battery spacing, plate width, and channel width remained the same as in the pack model.

The main advantage of this gradient design is that the downstream cells, which would otherwise overheat, receive additional cooling surface. Thus, the battery temperature can stay more nearly constant along the flow path.

5.2 Experimental validation of the CFD model

I constructed an experimental liquid-cooling platform using 18 cells, a coolant reservoir, a pump, a liquid flow meter, an aluminum cold plate, and thermal sensors. In the experiment, deionized water was used as the coolant to avoid corrosion and fouling of the tubing and pump. The cold plate was made from aluminum alloy by computer numerical-control machining. The cooling channels and manifolds were sealed carefully to prevent leakage.

Because the experimental apparatus uses volume flow rate rather than inlet velocity, the simulation velocity was converted to flow rate. The relation is:

$$
Q_{\mathrm{mL\,min^{-1}}} = V_{\mathrm{m\,s^{-1}}} \times A_{\mathrm{m^2}} \times 60 \times 10^{6}
$$

The physical properties of deionized water are given in Table 5.1.

Table 5.1 Properties of deionized water used for experimental validation
Property Value
Density / kg m-3 998.2
Specific heat capacity / J kg-1 K-1 4183
Thermal conductivity / W m-1 K-1 0.599

During validation, the coolant inlet temperature was set to 25 °C, the flow rate was 500 mL/min, and the cells were discharged at 2C. I measured the surface temperature of battery No. 1, No. 5, and No. 9 during the discharge process. These measured temperatures matched the numerical predictions closely. The maximum deviation between simulation and experiment was below 3%, which confirms that the CFD model is reliable for predicting temperature development in the gradient cold-plate module.

5.3 Gradient cold plate versus conventional cold plate

At a coolant flow rate of 240 mL/min, the conventional uniform cold plate produced a maximum battery temperature of 35.01 °C and a maximum temperature difference of 7.50 °C. In contrast, the gradient cold plate produced a maximum temperature of 33.23 °C and a temperature difference of 5.71 °C. Thus, the gradient structure reduced the maximum temperature by 5.08% and the maximum temperature difference by 23.56% compared with the uniform plate.

The improvement was particularly visible in the downstream region. In the conventional plate, the temperature continued to rise from cell 1 to cell 9. In the gradient plate, the temperature rose more slowly and even decreased after cell 3 and cell 6 because the local contact area increased at those positions. This behavior demonstrates that the gradient concept can break the usual monotonic temperature-rise pattern caused by coolant heating.

5.4 Influence of inlet flow rate on the gradient module

I performed a sweep of coolant flow rates from 120 to 720 mL/min in increments of 120 mL/min. The ambient and inlet temperatures were kept at 25 °C. Table 5.2 summarizes the results.

Table 5.2 Effect of coolant flow rate on battery module temperature
Flow rate / mL min-1 Maximum temperature / °C Maximum temperature difference / °C
120 36.58 8.07
240 33.23 5.71
360 32.20 5.11
480 31.81 4.98
600 31.56 4.91
720 31.37 4.86

Raising the flow rate from 120 to 240 mL/min produced the largest improvement. Further increases brought smaller thermal benefits. At 480 mL/min, the maximum temperature was 31.81 °C and the maximum temperature difference was 4.98 °C, which is below the 5 °C uniformity target. Therefore, 480 mL/min was considered to be the most suitable flow rate for the subsequent gradient-plate optimization because further flow increases consume more pump power without meaningfully improving temperature control.

5.5 Influence of cold-plate height gradient

In a gradient cold plate, the height of each segment can be adjusted. I fixed the initial height of the first cold-plate segment at 55 mm and added height increments from 2 to 7 mm to the second and third segments. When the height interval was small, the module temperature non-uniformity was relatively high. As the height interval increased, the maximum temperature and temperature difference both decreased. The benefit gradually saturated beyond a 5 mm interval. Therefore, a height increment of 5 mm was selected as the best design because it produced sufficient cooling-surface enhancement without excessive material cost.

5.6 Influence of length distribution gradient

In addition to changing the height stepwise, the longitudinal length of each segment can also be arranged in different ways. I kept the total cold-plate length unchanged and used six length configurations, expressed as the number of cells covered by each segment along the flow direction:

  • Configuration 1: 1-2-6, terminal-enhanced
  • Configuration 2: 1-3-5, interval-increasing
  • Configuration 3: 2-3-4, linear-increasing with terminal enhancement
  • Configuration 4: 2-5-2, extended middle segment
  • Configuration 5: 3-3-3, equal division
  • Configuration 6: 4-3-2, linearly decreasing length

The terminal-enhanced configuration 1-2-6 gave a maximum temperature of 31.40 °C and a maximum temperature difference of 4.55 °C. The linearly-increasing configuration 2-3-4 produced the same maximum temperature of 31.40 °C but a slightly larger difference of 4.57 °C. The equal-division configuration was used as the baseline; the terminal-enhanced design reduced the maximum temperature by 1.29% and the temperature difference by 8.63%. The linearly-decreasing configuration 4-3-2 showed the worst performance, with a maximum temperature of 32.18 °C and a temperature difference of 5.36 °C.

These results indicate that a larger cold-plate surface should be placed near the end of the flow path where the coolant is already warm. This targeted area enhancement is an effective way to equalize the temperature distribution inside a liquid-cooled EV battery module.

6. Conclusions and Outlook

In this study, thermal management solutions for cylindrical 21700 lithium-ion cells were analyzed through theory, experiments, and simulation. The major conclusions are as follows.

First, the internal resistance of the lithium-ion cell decreases when temperature rises and increases when SOC falls below 40%. The effect of temperature is especially strong at low temperatures. The measured resistance data were used to generate a SOC-dependent heat-source model. The simulation results agreed with measured cell surface temperatures within 3% for discharge currents of 0.5C, 1C, 1.5C, and 2C. Therefore, the proposed heat-source model is suitable for EV battery thermal simulations.

Second, eight semi-circular liquid-cooled plate structures were built around a 48-cell battery pack. The air-cooled baseline had a maximum temperature of 42.7 °C and a temperature difference of 11.77 °C, both too high for safe operation. Among the liquid-cooled structures, the S-shaped dual-channel series structure provided the lowest maximum temperature of 31.45 °C and the smallest temperature difference of 5.81 °C at the initial operating condition. Although its pressure drop was relatively high, further parameter optimization reduced the temperature difference below the 5 °C target. With a coolant velocity of 0.3 m/s, an inlet temperature of 25 °C, and a cold-plate height of at least 55 mm, the pack can operate within both the temperature and uniformity requirements.

Third, the gradient cold-plate design effectively solved the problem of temperature increase along the coolant-flow direction. By increasing the cold-plate contact area near the downstream cells, the temperature of the last cells in the module was reduced. Compared with the conventional non-gradient plate, the gradient plate decreased the maximum module temperature by 5.08% and the temperature difference by 23.56%. A coolant flow rate of 480 mL/min, a height increment of 5 mm, and a terminal-enhanced length distribution provided the best overall thermal performance.

Future work can extend this research to dynamic real-world driving cycles rather than constant current discharge. Low-temperature and high-temperature ambient conditions should also be investigated because EV battery thermal management is needed in both cold and hot climates. More detailed cell models that include aging and local heat-generation non-uniformity can also be included in the CFD model. Finally, the combination of advanced cold-plate layouts with model-predictive control algorithms will help to achieve efficient and reliable EV battery temperature control under all driving conditions.

Scroll to Top