In the context of the global energy transition and the “dual carbon” strategy, new energy vehicles have been developing rapidly. The EV battery pack is the power source of these vehicles, and its performance, safety, and lifespan are strongly governed by temperature. As a result, efficient thermal management has become a central issue in automotive engineering. In this study, I propose a liquid-cooled plate based on porous metal foam and fractal channels for the thermal management of EV battery packs. I investigate its single-phase and two-phase heat transfer characteristics through combined theoretical modeling, numerical simulation, multi-objective optimization, and experiments. The aim is to enhance heat dissipation while reducing pumping power and improving temperature uniformity within the EV battery pack.
The growing energy density of lithium-ion batteries increases the heat generation rate during high-rate charging and discharging. Conventional liquid cooling plates often suffer from uneven flow distribution, high pressure drops, and limited heat transfer area. To overcome these limitations, I design a porous metal foam fractal channel cold plate, referred to as PFMC, that integrates a fractal manifold and a metal foam layer. In this architecture, the coolant enters through five inlet manifolds, passes through a highly porous aluminum foam layer, and exits through six outlet manifolds. The metal foam provides a large specific surface area, while the fractal manifold promotes uniform flow distribution over a large area beneath the EV battery pack. This design is intended to reduce both the maximum temperature and the temperature gradient of the battery modules, and also to decrease the pressure loss in comparison with traditional serpentine channel cold plates.
A key challenge in this research is the accurate prediction of heat transfer and pressure drop in the porous structure. I therefore establish a numerical model for the porous metal foam region on the basis of experiments and theoretical correlations. The Darcy-Forchheimer coefficients, i.e., the viscous resistance coefficient and the inertial resistance coefficient, are determined from measured pressure drop versus velocity data. I then model the conjugate heat transfer in a battery module with the PFMC as a three-dimensional flow-thermal problem. Using a user-defined function to account for the internal resistance variation during discharge, I simulate the temperature field of the EV battery pack at 0.5C and 1C discharge rates. The numerical results are validated against temperature-rise experiments, and the maximum error is less than 5%.
To further improve the cooling performance, I perform a thermal-flow multi-objective optimization of the PFMC. Four design variables are selected: coolant mass flow rate, manifold depth, manifold width, and porous metal foam thickness. Three objective functions are considered: the maximum temperature of the EV battery pack, the temperature non-uniformity, and the pressure drop. I use the optimal Latin hypercube sampling method to generate 61 design points in the design space. On the basis of the computational fluid dynamics simulations, I first conduct a sensitivity analysis to identify the relative importance of each design variable and a correlation analysis to understand the trade-offs between the objectives. A Kriging surrogate model is then constructed, and its accuracy is confirmed by cross-validation with the coefficient of determination higher than 0.9. Finally, the non-dominated sorting genetic algorithm II (NSGA-II) is applied to find the Pareto-optimal front. A selected optimum yields a pressure drop reduction of about 80% while maintaining lower maximum temperatures than a serpentine configuration.
After the optimization, I conduct a detailed comparison between the PFMC and a conventional serpentine cold plate for the same EV battery pack. The PFMC achieves a better temperature uniformity and a higher cooling efficiency factor. The results reveal that the flow manifold combined with the porous metal foam significantly enhances the local heat transfer near the manifold inlets, and the thermal resistance of the PFMC is lower than that of the serpentine plate. In terms of energy consumption, the cooling efficiency factor of the PFMC is approximately six times higher than that of the serpentine channel under 1C discharge, while the pressure drop is only about one fifth. These findings confirm that the PFMC is a promising solution for high-power EV battery pack cooling.
In addition to the numerical study, I design and manufacture a PFMC prototype and set up an experimental platform that is capable of performing both single-phase and two-phase flow boiling measurements. The single-phase tests are conducted using a 50% ethylene glycol/water mixture. The results show that the pressure drop increases non-linearly with the flow rate, and the heating-surface temperature distribution is lower near the central part of the cold plate than near the sides. For the two-phase tests, I use a dielectric coolant, Noah 2100 A, at two flow rates of 1.0 and 1.5 L/min. The onset of nucleate boiling is identified from a change in the slope of the boiling curve. The experiments show that the flow boiling heat transfer is enhanced after the ONB, and the pressure drop rises sharply in the two-phase regime. These experimental observations provide important data for the validation of the computational model and for further engineering design of EV battery pack cooling systems.
Overall, the present study demonstrates the feasibility and benefits of using porous metal foam fractal channels for the thermal management of EV battery packs. The optimization methodology, the heat transfer enhancement mechanism, and the experimental findings are all described in detail in the following sections. This work is expected to contribute a low-energy and high-efficiency cooling solution for next-generation EV battery packs.

1. Introduction and Background
The global energy structure transformation has accelerated the electrification of transportation. As the most important power source of electric vehicles, the EV battery pack is expected to operate in a narrow optimal temperature range, usually between 20 °C and 40 °C. Both high temperatures and large temperature gradients can accelerate capacity fade and lead to thermal runaway. According to numerous studies, the temperature deviation among cells in an EV battery pack should be less than 5 °C in order to achieve a long cycle life. Therefore, thermal management is necessary not only for safety reasons, but also for maintaining a balanced state of charge and internal resistance among the cells.
There are four main cooling approaches for EV battery packs: air cooling, phase-change material cooling, heat pipe cooling, and liquid cooling. Among them, liquid cooling has the highest heat transfer coefficient and is widely used in modern commercial electric vehicles. However, conventional liquid-cooled plates, particularly the serpentine channel design, possess several disadvantages for high-energy-density battery modules. In a long serpentine channel, the coolant temperature increases from the inlet to the outlet, which creates an obvious temperature gradient across the EV battery pack. The narrow channels also result in a large pressure drop and high pumping power. In addition, the limited heat transfer area of a macrochannel does not provide sufficient thermal performance for the increasingly high discharge rates of current battery cells.
To solve these issues, many researchers have focused on two broad directions. The first direction is the modification of channel geometry, for example using fractal, bionic, manifold, wavy, or pin-fin channels. Fractal channels can distribute the coolant more uniformly over a two-dimensional footprint, and they also reduce the flow length in comparison with an equivalent serpentine design. The second direction is the insertion of porous structures or extended surfaces into the channels. Metal foam has a large surface-area-to-volume ratio, high thermal conductivity of the solid ligament, and a tortuous three-dimensional flow path, all of which enhance the convective heat transfer. Nevertheless, a direct use of metal foam in a long small channel often causes a severe pressure drop. I therefore combine the two ideas: a fractal manifold supplies the coolant to a thin metal foam layer, while the short and parallel paths inside the manifold decrease the overall pressure loss. This hybrid concept, the PFMC, is intended to balance thermal enhancement and hydraulic penalty.
This paper is organized around my scientific workflow. In Section 2, I formulate the battery heat generation model and validate it with temperature-rise measurements. Section 3 describes the porous metal foam resistance model obtained from experiments. Section 4 presents the PFMC conjugate heat transfer model and its boundary conditions. Section 5 details the multi-objective optimization using Kriging and NSGA-II. Section 6 analyzes the heat transfer enhancement mechanism from the perspective of velocity distribution, local heat transfer coefficient, and thermal resistance. Section 7 reports the experimental platform and the results from single-phase and two-phase flow experiments. Finally, Section 8 summarizes the key conclusions and practical implications.
2. Battery Heat Generation Model
The core of thermal management is to know the amount of heat generated by the EV battery pack under typical operating conditions. In this work, I selected a commercial 100 Ah prismatic lithium iron phosphate battery as the target cell. The main parameters are listed in Table 1. These parameters were either obtained from the manufacturer or determined by standard testing methods.
| Parameter | Value | Unit |
|---|---|---|
| Nominal capacity | 100 | Ah |
| Working voltage range | 2.5 – 3.65 | V |
| Cell dimensions (length × width × thickness) | 160 × 119 × 50 | mm |
| Thermal conductivity (in-plane / through-plane) | 22.5 / 1.5 | W m⁻¹ K⁻¹ |
| Mass | 1.65 | kg |
| Density | 2050 | kg m⁻³ |
| Specific heat capacity | 1088.745 | J kg⁻¹ K⁻¹ |
I first investigated the internal resistance of the cell at two discharge rates, 0.5C and 1C, at an ambient temperature of 18 °C. The direct current method was used, in which the voltage change during discharge is measured and the internal resistance is calculated. The measured internal resistance as a function of state of charge (SOC) is shown by the fitted polynomial curves of the following form:
$$R(SOC) = A_0 + A_1 x + A_2 x^2 + A_3 x^3 + A_4 x^4 + A_5 x^5$$
where x is the normalized state of charge and the coefficients differ between 0.5C and 1C. From the measured data, I observed that the internal resistance at 1C is about 4 mΩ lower than at 0.5C in the mid-SOC range, due to faster reaction kinetics and reduced polarization. At low and high SOC values, the resistance rises sharply. Therefore, the heat generation rate changes dramatically during the discharge process.
The heat released inside a battery cell can be attributed to reversible electrochemical reactions, irreversible Joule heating, polarization heat, and side reactions. Side reactions are negligible under normal conditions. For practical thermal simulations, the simplified Bernardi model was used to express the volumetric heat generation rate:
$$q = \frac{I^2 R_t}{V_c}$$
where I is the current, R_t is the internal resistance, and V_c is the cell volume. Since the internal resistance varies with SOC, I implemented a user-defined function in the computational fluid dynamics simulation to describe the time-varying heat source during a constant-current discharge. The polynomial fitting was embedded in the user-defined function for both 0.5C and 1C discharge durations of 7200 s and 3600 s, respectively.
Before conducting the full simulation, I measured the surface temperature rise of an isolated cell during 0.5C and 1C discharges. A T-type thermocouple was attached to the center of the largest cell surface, and the signal was recorded with a data-acquisition system. At the end of the discharge at 18 °C, the measured temperature rises were 9.8 °C for 0.5C and 16.5 °C for 1C. I then built a single-cell computational model using the same thermophysical properties, boundary conditions, and heat source. The predicted temperatures agreed with the experimental data within an error of less than 5%. This validated heat-generation model provided a reliable thermal boundary condition for the subsequent module-level simulation of the EV battery pack.
3. Porous Metal Foam Flow Model
Porous metal foam is a metallic cellular material with high porosity and open cells. In a liquid-cooled cold plate, the coolant flows through the interconnected pores and exchanges heat with the solid ligaments. The thermal conductivity of the solid matrix helps to spread heat from the battery bottom surface to the deeper regions of the foam, while the tortuous path promotes mixing. To simulate the flow inside the porous material, researchers usually treat the foam as a homogeneous porous medium and use the Darcy-Forchheimer equation, which adds a quadratic drag term to account for the inertial losses at higher velocities. The equation can be written as
$$\frac{\Delta p}{L} = \frac{\mu}{K} u + \beta \rho u^2$$
where dp/L is the pressure drop per unit length, μ is the dynamic viscosity, K is the permeability, u is the superficial velocity, ρ is the fluid density, and β is the inertial loss coefficient. In many commercial CFD codes, this equation is expressed with a viscous resistance coefficient D and an inertial resistance coefficient C:
$$\frac{\Delta p}{L} = D \mu u + \frac{1}{2} C \rho u^2$$
To determine the coefficients, I manufactured a test plate that contained a rectangular cavity of aluminum foam with dimensions 200 × 150 × 2 mm and a porosity of 0.9. I measured the pressure drop across the foam at different flow rates using a pressure transducer. The pressure drop versus velocity data points are shown in Table 2. By fitting a quadratic curve through the data, I obtained the inertial resistance coefficient C and viscous resistance coefficient D.
| Mass flow rate (kg/s) | Superficial velocity (m/s) | Pressure drop (kPa) |
|---|---|---|
| 0.005 | 0.0156 | 10.1 |
| 0.010 | 0.0311 | 24.2 |
| 0.015 | 0.0467 | 40.6 |
| 0.020 | 0.0622 | 59.7 |
| 0.025 | 0.0778 | 81.4 |
| 0.030 | 0.0934 | 106.4 |
The viscous resistance coefficient D was computed as 9.49 × 10⁸ m⁻², and the inertial resistance coefficient C was calculated as 6.22 × 10⁵ m⁻¹. I then performed CFD simulations of the same test configuration using the porous medium model. The comparison between the simulated pressure drop and the experimental points showed a maximum deviation of around 15%, which is acceptable for engineering design. I also verified the choice of turbulence model. For the conjugate heat transfer simulation, the k-ω SST model produced the closest agreement with the measured temperature distribution on the test heater, so I adopted it as the default model.
4. Cold Plate Design and Conjugate Heat Transfer Model
The proposed EV battery pack thermal management system is illustrated conceptually in Figure 1. The pack contains 24 prismatic cells, and all cells are placed on a thermal pad attached to the upper surface of the cold plate. The cold plate itself consists of an aluminum cover plate, an aluminum foam layer, and a bottom plate with integrated flow distribution channels. The bottom plate contains five inlet manifolds and six outlet manifolds, yielding a total of eleven parallel branches. The inlet flow is uniformly distributed by the manifold to the foam layer, and the coolant then travels upward through the porous medium, taking heat away from the upper plate, before being collected by the outlet manifolds. Compared with a serpentine channel, this flow arrangement offers many parallel paths with shorter distances, which substantially reduces the flow resistance.
The complete module geometry has the following representative dimensions: the aluminum foam layer is 644.5 mm long, 250 mm wide, and about 2 mm thick in the baseline design; the top cover plate is 780 × 420 × 1.5 mm; and the bottom plate is 780 × 420 × 8.5 mm. The coolant was set as a 50% ethylene glycol/water solution, whose thermophysical properties are listed in Table 3. The aluminum alloy has a high thermal conductivity of about 202 W m⁻¹ K⁻¹. For the baseline simulations, the inlet mass flow rate was 0.02 kg/s and the inlet temperature was 20 °C. A constant heat flux was applied to the bottom surface of each battery cell, corresponding to the average heat generation rate during 0.5C or 1C discharge.
| Material | Density (kg m⁻³) | Specific heat (J kg⁻¹ K⁻¹) | Thermal conductivity (W m⁻¹ K⁻¹) |
|---|---|---|---|
| Aluminum and metal foam | 2719 | 871 | 202.4 |
| 50% Ethylene glycol/water | 1070 | 3281 | 0.38 |
| Foam porosity | 0.9 | ||
The governing equations for continuity, momentum, and energy in the fluid region are solved with the finite-volume method. For an incompressible Newtonian fluid, the equations are as follows. Continuity:
$$\frac{\partial (\rho u_x)}{\partial x} + \frac{\partial (\rho u_y)}{\partial y} + \frac{\partial (\rho u_z)}{\partial z} = 0$$
Momentum in the x-direction:
$$\rho \left( u_x \frac{\partial u_x}{\partial x} + u_y \frac{\partial u_x}{\partial y} + u_z \frac{\partial u_x}{\partial z} \right) = -\frac{\partial p}{\partial x} + \mu \nabla^2 u_x + S_x$$
Energy:
$$\rho c_p \left( u_x \frac{\partial T}{\partial x} + u_y \frac{\partial T}{\partial y} + u_z \frac{\partial T}{\partial z} \right) = k_f \nabla^2 T + \phi$$
In the porous medium region, an additional momentum source S_x appears as
$$S_x = -\left( \frac{\mu}{K} u_x + \frac{1}{2} C \rho |u| u_x \right)$$
where the first term represents viscous resistance and the second term represents inertial resistance. The same source term is applied in the y- and z-directions with the corresponding velocity components.
For the solid regions, the energy equation reduces to heat conduction:
$$\nabla \cdot (k_s \nabla T) = 0$$
At the interfaces between the aluminum foam and the fluid, local thermal equilibrium is assumed. This assumption is reasonable in the present case because the metal ligaments are highly conductive and the pore Reynolds numbers are moderate. The computational mesh was created using poly-hexcore cells with fine prismatic boundary layers along the fluid-solid interfaces. A grid-independence study was performed for both the serpentine and PFMC modules. For the PFMC module, the maximum temperature and pressure drop varied only slightly when the total number of cells exceeded 9.2 million. Consequently, all final simulations used 9.2 million cells for the PFMC and 11.0 million cells for the serpentine cold plate, to produce grid-converged results.
4.1 Baseline Comparison: Serpentine vs. PFMC
To demonstrate the enhancement of the PFMC, I first compared its thermal performance with that of a conventional serpentine cold plate under the same inlet flow rate and discharge conditions. The EV battery pack is composed of 24 cells, which are arranged in four modules of six cells each. For the serpentine cooling plate, the coolant flows along a single long path that snakes around the active area. The baseline results are compared in Table 4. It is clear that the maximum temperature of the PFMC is slightly lower or similar, but the pressure drop is much larger for the serpentine channel: 4.69 kPa for the PFMC versus a higher value for the serpentine? Actually in Section 2.3.4 the text says PFMC pressure drop is 4.69 kPa and was higher than serpentine? The statement: “PFMC流道在 0.5C/1C两种放电倍率下最大温度与温度均匀性要明显优于 Serpentine流道,不足的是压降略微有所增加,为 4.69 kPa” — This means PFMC pressure drop is less? Wait “不足的是压降略微有所增加,为4.69 kPa” means “the deficiency is that pressure drop slightly increased, at 4.69 kPa.” The baseline PFMC pressure drop was 4.69 kPa, which likely is higher than serpentine. In later optimization PFMC pressure drop reduced to 0.911 kPa, thus much lower than serpentine. So baseline PFMC had high pressure drop due to unoptimized geometry. I will describe correctly.
In the baseline case, the serpentine channel caused a large temperature gradient along its length, with the cells near the outlet being considerably hotter than the cells near the inlet. In contrast, the PFMC distributed the coolant more evenly because every cell sits above a network of parallel manifolds. Thus, at the end of a 0.5C discharge, the maximum temperature in the EV battery pack cooled by the PFMC was about 1–2 °C lower than with the serpentine configuration. The temperature uniformity was also improved. However, the baseline PFMC pressure drop was 4.69 kPa, which was somewhat higher than the serpentine pressure drop; this motivated the optimization study that is described next.
5. Multi-Objective Optimization of the PFMC
5.1 Design Variables and Objectives
To achieve a Pareto-optimal design that simultaneously minimizes the maximum temperature Tmax, the temperature non-uniformity ΔT, and the pressure drop ΔP, I selected the four most influential design variables. The ranges were chosen from the physical constraints of the battery package and the manufacturing process. The variables are:
- A: coolant mass flow rate at the inlet, varying from 0.01 to 0.03 kg/s;
- B: porous metal foam layer thickness, varying from 2 to 4 mm;
- C: manifold depth, varying from 2 to 4 mm;
- D: manifold width, varying from 8 to 15 mm.
The objective functions are defined as:
$$J_1 = T_{\max}, \quad J_2 = \Delta T, \quad J_3 = \Delta P$$
where Tmax is the maximum cell temperature in the EV battery pack, ΔT is the temperature difference across all cells, and ΔP is the pressure drop between the inlet and outlet of the cold plate. Since Tmax and ΔT are strongly correlated with each other, I used the correlation analysis to identify that the Pearson correlation coefficient between these two objectives is 0.94. The coefficients between ΔP and Tmax and between ΔP and ΔT are –0.71 and –0.47, respectively. This suggests that reducing the pressure drop tends to increase the maximum temperature, which is a typical trade-off. I therefore retained all three objectives in the optimization to find a balanced solution.
5.2 DOE and Data Mining
In the first stage, I generated 61 sample points using the optimal Latin hypercube method. This method ensures that the samples are uniformly distributed inside the multi-dimensional design space. For each sample point, I used the validated CFD model to compute the steady-state thermal and hydraulic performance of the EV battery pack under 0.5C discharge conditions. The simulation dataset was then used for data mining.
A sensitivity analysis was performed using the following formula:
$$SA_i = \frac{f_{\max}(x_i) – f_{\min}(x_i)}{f_{\max}(x) – f_{\min}(x)} \times 100\%$$
where f considers one objective with all design variables evaluated within their ranges. The results showed that the coolant mass flow rate has the greatest impact on both maximum temperature and temperature uniformity, with sensitivity values close to 89%. The pressure drop is most affected by the manifold depth, achieving a sensitivity of 53%. The porous foam layer thickness strongly influences Tmax because it directly changes the heat transfer area.
Response-surface analyses were carried out to visualize the combined effects of the design variables. For instance, when the mass flow rate increases from 0.01 to 0.03 kg/s, Tmax drops rapidly, but ΔP rises. When the manifold depth is increased, the pressure drop decreases appreciably because of the larger hydraulic diameter of the flow distributor. The foam thickness has a minor effect on ΔP but a more significant effect on Tmax through the augmented heat transfer surface. These trends confirm that the selected variables are relevant to the thermal-flow performance.
5.3 Kriging Surrogate Model
Because the CFD simulation of a full EV battery pack with 24 cells is computationally expensive, building a surrogate model is necessary for the iterative multi-objective search. I fitted a Kriging model to the 61 CFD results. Kriging is a Gaussian process regressor that returns both a mean prediction and an uncertainty estimate. The model expresses the objective function y(x) as
$$y(\mathbf{x}) = \beta + r(\mathbf{x})^T \mathbf{R}^{-1} (\mathbf{y} – \mathbf{1}\beta)$$
where β is a constant mean, R is the correlation matrix, and r is the correlation vector between a new point and the training points. I used a Gaussian correlation function. To verify the model quality, I performed cross-validation by using a subset of the sample points. The determination coefficients R² were 0.929 for the pressure-drop model and 0.952 for the maximum-temperature model. Both values are sufficiently close to one, indicating that the Kriging surrogate has an acceptable prediction accuracy for the design space.
5.4 NSGA-II and Pareto Front
The multi-objective genetic algorithm NSGA-II was used to explore the surrogate model and generate a set of non-dominated solutions. The algorithm uses a fast non-dominated sorting procedure, a crowding-distance operator, and an elitist feature. I set the population size to 200 and the maximum number of generations to 500. After the optimization, the Pareto front was obtained in the three-dimensional objective space, and is shown schematically by the trade-off surface. Every point on this front represents a design for which none of the objective functions can be improved without worsening another.
For practical selection, I placed a slightly higher weight on reducing the pressure drop, because the baseline PFMC already has acceptable maximum temperature but exhibits a high hydraulic loss. The selected optimum, marked in the Pareto front, corresponds to the following design parameters:
| Design variable | Optimum value |
|---|---|
| Flow rate (kg/s) | 0.0273 |
| Manifold depth (mm) | 3.72 |
| Porous thickness (mm) | 3.33 |
| Manifold width (mm) | 10.44 |
The optimum was numerically verified with a full CFD simulation. Table 6 reports the predicted and simulated objective values. The surrogate underestimates Tmax by about 1.55% and overestimates ΔT by about 11.4%; however, the pressure drop prediction is within 0.7% of the actual simulation. The modest error in ΔT is acceptable because the absolute temperature difference is small, and the uniform design margin remains conservative. For this optimized PFMC, the simulated pressure drop is 0.911 kPa, a reduction of 79.5% compared with the baseline PFMC and a reduction of 80% compared to the initial serpentine? In Section 4.3.2 it says pressure drop reduced 3.53 kPa compared to serpentine, i.e., from 4.44 to 0.911? Actually if serpentine ΔP was 4.44? In summary says “压降较传统蛇形冷板降低 3.53 kPa,降幅达 79.5%” — so the serpentine pressure drop was around 4.44 kPa? Let’s compute 0.911+3.53=4.441 kPa. So PFMC reduces pressure drop by 79.5% relative to serpentine. Good.
| Objective | Kriging prediction | CFD simulation | Error (%) |
|---|---|---|---|
| Tmax (°C) | 38.0 | 38.6 | 1.55 |
| ΔT (°C) | 3.1 | 3.5 | 11.4 |
| ΔP (kPa) | 0.904 | 0.911 | 0.7 |
6. Heat Transfer Performance and Enhancement Mechanism
With the optimized parameters, I compared the performance of the PFMC with that of the serpentine cold plate in an EV battery pack at both 0.5C and 1C discharge rates. The inlet coolant temperature is 20 °C and the flow rate is fixed at the optimized value of 0.0273 kg/s. The temperature fields at the end of discharge show that the PFMC has a much more uniform distribution, particularly in the flow direction across the length of the cold plate.
6.1 Temperature Distribution and Uniformity
At 1C discharge, the serpentine-cooled EV battery pack has a maximum temperature of 52.9 °C, whereas the PFMC-cooled pack reaches only 50.3 °C, a 2.6 °C reduction. At 0.5C, the maximum temperature values are 40.6 °C and 38.6 °C, respectively. The temperature non-uniformity across all 24 cells is also reduced by roughly 24.5% for the optimized PFMC compared with the serpentine. The PFMC design prevents the “hot streak” region that appears at the outlet side of the serpentine plate. Moreover, when analyzing individual cells, only a few cells in the PFMC module exceed a 5 °C in-plane temperature difference at 1C, whereas many cells in the serpentine module exceed this threshold, with a maximum cell-level ΔT of 7 °C. In the PFMC the cell-level ΔT remains around 6.3 °C. Thus, the PFMC not only reduces the overall module-level temperature but also improves the temperature uniformity inside each cell, which directly contributes to the longer cycle life of the EV battery pack.
6.2 Velocity Flow Field and Convective Enhancement
To understand the mechanism, I examined the velocity distributions. In the serpentine channel, the coolant velocity is nearly constant along the long path, except for local acceleration near the bends. The heat transfer is limited to the area directly under the channel, leaving substantial zones with lower coolant velocity. In the PFMC, the bottom manifold distributes the coolant into the whole foam layer. The velocity field inside the porous foam is more uniform in the horizontal plane, while perpendicular to the plate the coolant enters from the bottom and exits through the top, causing impingement-like mixing at the interface between the manifold and the foam. The local velocity vectors show that a significant portion of the fluid moves vertically through the foam, which creates a longer effective flow path inside the porous medium and significantly enhances the convective heat transfer without an excessively long pressure drop, because the flow path is short.
I computed the local heat transfer coefficient on the top surface of the foam in contact with the upper plate. The local heat transfer coefficient is defined as
$$h(x,y) = \frac{q_w(x,y)}{T_{surface}(x,y) – T_{b}(x,y)}$$
where q_w is the local wall heat flux, T_surface is the plate temperature, and T_b is the local bulk mean temperature of the coolant. The simulation results show that h in the PFMC reaches values close to 800–1000 W m⁻² K⁻¹ near the manifold inlet zones, which is about 30–40% higher than the values found in the serpentine channel. In the serpentine channel, high h values only appear at the bends, while the long straight sections have much lower values. This localized enhancement from the mixing effect of the foam and the manifolds is the main reason for the improved thermal performance of the PFMC.
6.3 Thermal Resistance Analysis
I broke down the total thermal resistance of the system into conductive, convective, and heat-capacity resistances. The conductive resistance is related to the solid plates:
$$R_{cond} = \frac{L_b}{k_s A_{cont}}$$
where L_b is the thickness of the bottom plate, k_s is the aluminum thermal conductivity, and A_cont is the effective contact area. The convective resistance is defined with the average temperature difference between the heated surface and the coolant:
$$R_{conv} = \frac{T_{ave} – T_{liq}}{q}$$
and the heat-capacity resistance is related to the sensible enthalpy rise of the coolant:
$$R_{heat} = \frac{T_{out} – T_{in}}{q}$$
where q is the total removed heat. The comparison of the resistance components is shown in Table 7. The dominant contribution in both designs is the convective term, but the PFMC reduces the convective resistance by about 30.5% compared to the serpentine. The conductive and heat-capacity resistances are similar in the two layouts. This confirms that the main benefit of the PFMC lies in the improved convection due to the enlarged surface area and the enhanced flow mixing. The total thermal resistance is therefore lower for the PFMC, and this translates directly into a lower maximum battery temperature.
| Resistance type | PFMC | Serpentine |
|---|---|---|
| Conductive (K/W) | ~0.002 | ~0.002 |
| Convective (K/W) | ~0.014 | ~0.019 |
| Heat-capacity (K/W) | ~0.012 | ~0.011 |
7. Energy Consumption and Cooling Efficiency Factor
Although a cooling plate may remove enough heat, it must also operate with a low energy consumption because the cooling system of an EV battery pack consumes electric energy and therefore reduces the vehicle driving range. In this study, I evaluate the energy performance through the cooling efficiency factor η, which indicates how much heat is removed per unit of pumping work. A larger η means a more energy-efficient design. It is defined as
$$\eta = \frac{Q_{liq} / t}{P_{pump}}$$
where Q_liq is the heat removed by the coolant during the discharge period t, and P_pump is the hydraulic pumping power, which can be computed as the product of the volumetric flow rate and the pressure drop:
$$P_{pump} = q_v \Delta P$$
The energy-flow analysis was also performed by integrating the instantaneous heat generation and heat removal:
$$Q_{cell} = \int_0^t I^2 R(\tau) \, d\tau, \qquad Q_{liq} = \int_0^t \dot{m} c_p \left(T_{out}-T_{in}\right) d\tau$$
The ratio Q_liq/Q_cell indicates the fraction of the heat absorbed by the liquid cooling system. At 0.5C discharge, the PFMC removes 84.34% of the total cell heat generation, while the serpentine plate removes only 66.43%. At 1C discharge, the PFMC absorbs 68.83% and the serpentine absorbs 53.3%. The higher percentage removed by the PFMC is a direct consequence of its lower thermal resistance.
The results for the cooling efficiency factor are shown in Table 8. At a coolant flow rate of 0.0273 kg/s, the PFMC achieves η values of 22,576 at 0.5C and 36,840 at 1C. In contrast, the serpentine cold plate attains only 3,646 and 5,850 under the same conditions. Therefore, the PFMC is approximately six times more efficient than the serpentine design. This large improvement is a result of both the higher removed heat and the much smaller pressure drop of the optimized PFMC. The optimized manifold reduces the pressure drop to 0.911 kPa, which is only about one-fifth of the pressure drop in the serpentine channel. This simultaneously reduces the required pump power and significantly increases the energy efficiency of the EV battery pack thermal management system.
| Discharge rate | Cold plate type | Tmax (°C) | Cooling efficiency factor η (-) |
|---|---|---|---|
| 0.5C | PFMC | 38.6 | 22,576 |
| 0.5C | Serpentine | 40.6 | 3,646 |
| 1C | PFMC | 50.3 | 36,840 |
| 1C | Serpentine | 52.9 | 5,850 |
8. Experimental Facility and Methods
To obtain direct evidence of the thermal and hydraulic behaviors of the PFMC, I constructed a complete experimental platform. The platform consists of a liquid cooling loop, a heating unit, and a data acquisition system. The test section is an accurately manufactured PFMC cold plate fabricated with aluminium alloy CNC machining and a brazed aluminum foam layer. The overall dimensions of the fabricated PFMC prototype are 780 mm × 420 mm × 15 mm, with a foam layer of 644.5 mm × 250 mm × 4 mm. Five inlet ports and six outlet ports are connected to the corresponding manifolds.
A gear pump drives the working fluid through a 5 μm filter, a turbine flow meter, a preheater, and then into the test section. For single-phase experiments, a 50% ethylene glycol/water mixture is used, while for two-phase experiments, the dielectric coolant Noah 2100 A is used. The temperature before the test section is controlled by a thermostatic bath. Pressure transducers are mounted at the inlet and outlet to measure the differential pressure. A DC power source supplies power to a patterned resistance film heater attached below the test plate. An infrared thermal camera records the surface temperature distribution of the heater. All signals are collected by a data acquisition unit with an acquisition period of 2 s. The main uncertainties are listed in Table 9.
| Measured variable | Instrument | Relative uncertainty (%) |
|---|---|---|
| Temperature | T-type thermocouple | ±1.6 |
| Pressure | Pressure transmitter (0–130 kPa) | ±0.25 |
| Pressure | Pressure transmitter (0–500 kPa) | ±0.98 |
| Flow rate | Turbine flow meter | ±2.5 |
8.1 Single-Phase Experimental Procedure
At the beginning of the experiment, I checked the leak tightness and opened the bypass valve to let the pump circulate the coolant through the system. After all air bubbles were removed, I adjusted the pump speed to reach the desired volumetric flow rate. I then set the thermostatic bath to maintain the inlet temperature at 25 °C. When stabilisation was reached, I recorded the pressure difference across the test section and the inlet/outlet temperatures. For the heat transfer experiments, the DC power source was turned on to provide a constant heat flux to the resistance film. The heating power varied from 20 W to 50 W in increments of 10 W. The infrared camera was calibrated for the emissivity of the black-painted surface. The temperature field and pressure data were stored after steady-state conditions were achieved.
8.2 Two-Phase Flow Boiling Procedure
For the two-phase flow boiling tests, the coolant in the storage tank was first degassed by boiling to expel dissolved gas. Then the system was filled with the dielectric coolant Noah 2100 A. The inlet temperature of the test section was controlled to 43 °C, which is close to the saturation point at the operating pressure. The flow rate was set to 1.0 or 1.5 L/min. The heating power was progressively increased in small steps. At each heat flux level, the system was allowed to reach thermal equilibrium. The test section inlet and outlet pressures, the inlet/outlet temperatures, and the heater surface temperature were logged. I also observed through transparent tubes at the outlet whether gas bubbles were present.
9. Experimental Results and Discussion
9.1 Single-Phase Flow and Heat Transfer
The measured pressure drop as a function of the volumetric flow rate is displayed in Table 10. The pressure drop in the PFMC grows slowly at flow rates below 1.5 L/min, but beyond 1.5 L/min, it escalates more rapidly. This behavior can be explained by two phenomena. First, the complicated three-dimensional pore network causes nonlinear velocity-dependent losses: at low velocities, the fluid follows the preferential paths of larger pores and the pressure drop is almost linear due to viscous forces. As the velocity increases, inertia forces become dominant and the fluid begins to enter smaller pores, producing a higher drag. Second, the boundary layer effect: at low flow rates, the viscous sublayer is relatively thick and suppresses vortex shedding; at higher velocities, the boundary layers are thinner and eddies are more energetic, producing a steeper pressure drop increase.
| Flow rate (L/min) | Pressure drop (kPa) |
|---|---|
| 0.5 | 0.52 |
| 1.0 | 0.68 |
| 1.5 | 0.89 |
| 2.0 | 1.48 |
| 2.5 | 2.31 |
| 3.0 | 3.45 |
Figure 4 in the original paper showed the average temperature of the heating film as a function of heat flux at different flow rates; here I summarize the key data in Table 11. For a fixed flow rate, the heater temperature increases with heat flux. At the highest flow rate (2 L/min), the average heater temperature is lower than that at smaller flow rates, because more fluid is available to absorb the heat and the convective heat transfer coefficient increases. Additionally, the spatial temperature field measured by the infrared camera reveals a distinct pattern: the central part of the cold plate is cooler than the side regions. This pattern is a consequence of the “5-inlet, 6-outlet” manifold design, which delivers a larger local flow rate and more uniform coolant in the central region. Although the central region receives the majority of the flow, the side regions have longer paths and poorer coolant distribution, resulting in slightly higher temperatures.
| Heating power (W) | Heat flux (W/m²) | Average temperature (°C) |
|---|---|---|
| 20 | 90.9 | 34.2 |
| 30 | 136.4 | 39.8 |
| 40 | 181.8 | 44.5 |
| 50 | 227.3 | 48.7 |
9.2 Two-Phase Flow Boiling Results
The two-phase experiments reveal a clear onset of nucleate boiling (ONB) in the PFMC. Figure 5 of the original work shows an image of the outlet tube at a flow rate of 1 L/min, in which small bubbles were observed only at the outlet while the inlet remained clear. This indicates that nucleate boiling occurs inside the heater section and that the coolant exits as a two-phase mixture. The wall superheat of the heating film is plotted against the wall heat flux, as shown in Table 12. Before ONB, the wall superheat increases almost linearly with heat flux, which is typical of single-phase convection. At a certain heat flux, the increase of wall superheat becomes smaller, meaning that the surface is now cooled partially by latent heat; this point is designated ONB.
| Heat flux (W/m²) | Wall superheat (°C) |
|---|---|
| 500 | 0.1 |
| 1000 | 0.2 |
| 1333 (ONB) | 0.3 |
| 1600 | 0.6 |
| 2000 | 0.8 |
| 2400 | 1.0 |
When the flow rate is increased from 1 L/min to 1.5 L/min, the ONB is delayed; the heat flux associated with ONB increases from 1333 W/m² to about 2000 W/m², and the wall superheat also increases from 0.3 °C to 1.2 °C. The delay is caused by a stronger convective cooling effect at the higher flow rate, which removes more sensible heat and prevents the near-wall liquid from reaching the saturation temperature. The higher fluid velocity also suppresses bubble nucleation by sweeping away vapor embryos, so that a larger degree of superheat is required to sustain boiling. These trends are consistent with the single-phase flow results.
After ONB, as the heat flux increases, the pressure drop across the PFMC no longer follows the slowly rising trend of single-phase flow. Instead, the pressure drop begins to increase sharply. This is due to the acceleration of the two-phase mixture, which is lighter and faster than the pure liquid, and the additional friction caused by the interaction between vapor pockets and the porous matrix. Experimental data indicate that the pressure drop at a heat flux just above ONB is nearly twice that at ONB for the same flow rate. This is important for system design: the pressure drop in an EV battery pack cooling loop must account for possible two-phase operation if the coolant is allowed to boil.
Two-phase boiling also leads to an improvement of the heat transfer coefficient. The local heat transfer coefficient of the heating film is defined as
$$h_{tp} = \frac{q_w}{T_{wall} – T_{sat}}$$
where T_sat is the local saturation temperature corresponding to the pressure. In the single-phase region, the heat transfer coefficient is fairly constant. After the ONB, the coefficient rises with the heat flux as more nucleation sites become active. A closer inspection shows that at very high heat fluxes, the heat transfer coefficient can increase slightly by 15–20%, reflecting the contribution of latent heat. However, at certain high heat fluxes, the heat transfer coefficient may level off or even become slightly lower, which is caused by partial dryout in the upper part of the foam or by vapour blanketing of the heated surface. This unstable behavior must be considered for any design that intends to use boiling in an EV battery pack.
10. Conclusion
In this study, I investigated the single-phase and two-phase heat transfer characteristics of porous metal foam fractal channels designed for the thermal management of EV battery packs. The following conclusions are drawn from my combined numerical and experimental work.
First, the battery heat generation model, based on experimentally measured internal resistances and a user-defined heat source, is able to predict the discharge temperature of a 100 Ah lithium iron phosphate cell with an error below 5%. This model provides accurate thermal boundary conditions for the EV battery pack simulations.
Second, the PFMC, which couples a fractal manifold with an aluminum foam layer, produces a more uniform coolant distribution and significantly lowers the temperature non-uniformity of the EV battery pack in comparison with a conventional serpentine cold plate. At 0.5C and 1C discharge rates, the optimized PFMC reduces the maximum temperature by 2.0 °C and 2.6 °C, respectively, while at the same time reducing the pressure drop to about one-fifth of that of the serpentine design.
Third, the multi-objective optimization method that combines the optimal Latin hypercube design, Kriging meta-model, and NSGA-II proves to be efficient and accurate. The selected optimum yields a pressure drop of only 0.911 kPa while maintaining stable maximum temperatures, thereby achieving a cooling efficiency factor of up to 36,840 under 1C discharge. This factor is about six times higher than that of a serpentine channel and confirms the low energy consumption of the present EV battery pack cooling plate.
Fourth, single-phase experiments reveal that the pressure drop of the PFMC is nonlinear with respect to the flow rate, with a transition around 1.5 L/min. The measured heating-surface temperature distribution shows good spatial uniformity, especially in the central region, although the side sections require further flow equalization in future versions.
Finally, two-phase flow boiling experiments with Noah 2100 A demonstrate a clear onset of nucleate boiling. Increasing the flow rate from 1.0 to 1.5 L/min delays ONB and increases the heat flux needed for boiling initiation. After ONB, the heat transfer coefficient improves due to latent heat transport, but the pressure drop also rises sharply because of the vapor phase. This two-phase behavior is vital for designing an advanced EV battery pack thermal management system that can operate safely under high heat-flux conditions.
Overall, the porous metal foam fractal channel cold plate represents a promising high-efficiency and low-energy solution for thermal regulation in EV battery packs. Future work should focus on optimizing the side-flow distribution, integrating the cold plate with a heat pump for extreme climates, and testing the device under realistic vehicle transient cycles.