Fault Diagnosis for Electric Vehicle Battery Packs

I began this work from a practical concern: the electric vehicle battery pack is the central energy-storage unit of an electric vehicle, and its safety, reliability, and durability directly affect vehicle performance and occupant protection. As global attention to energy shortages and environmental pollution has increased, electrified transportation has become a strategic direction. The electric vehicle battery pack is not a single cell but a complex system composed of many cells, connectors, sensors, wiring harnesses, thermal-management components, and a battery management system. Because the electric vehicle battery pack operates under vibration, current fluctuation, temperature variation, and long-term cycling, faults can appear gradually and can be hidden inside otherwise normal-looking voltage signals. I therefore focused my research on two important faults: virtual connection faults and micro-short-circuit faults in the electric vehicle battery pack.

In my view, the most urgent problem is not only detecting a fault after it becomes obvious, but identifying it early enough to prevent thermal runaway, fire, or sudden loss of power. A loose connector inside an electric vehicle battery pack can create a high-resistance contact. Under road-induced vibration, this contact resistance can fluctuate abruptly, producing abnormal voltage changes and local heating. A micro-short circuit inside an electric vehicle battery pack is even more challenging because its early leakage current is small, its voltage drop is subtle, and its thermal signature may be masked by normal operating conditions. I designed my research to address both faults with data-driven methods, signal-processing methods, and quantitative model-based reasoning.

I studied the structure and operating principles of lithium-ion cells because the behavior of the electric vehicle battery pack cannot be understood without understanding the cell. A lithium-ion cell contains a positive electrode, a negative electrode, an electrolyte, a separator, current collectors, and packaging. During charging, lithium ions move from the positive electrode to the negative electrode, while electrons flow through the external circuit. During discharging, the process reverses. The separator prevents direct contact between the positive and negative electrodes, but it allows lithium ions to pass. This design gives lithium-ion cells high energy density, high power density, low self-discharge, and long cycle life, which explains why they dominate the electric vehicle battery pack market.

The choice of electrode materials strongly affects the electric vehicle battery pack. I summarized the main cathode materials and their properties in the following table.

Cathode material Specific energy (Wh/kg) Maximum charge rate (C) Maximum discharge rate (C) Cycle life Safety Cost
Lithium cobalt oxide 150-200 0.7-1 1 500-1000 Medium High
Lithium manganese oxide 100-150 0.7-1 1 300-700 High High
Lithium iron phosphate 90-120 1 2 1000-2000 Medium High
Nickel cobalt manganese oxide 150-220 0.7-1 2 1500-2000 High Medium
Nickel cobalt aluminum oxide 200-260 0.7 1 500-1000 Medium Medium

I also compared common anode materials because the negative electrode influences capacity, cycle life, rate capability, and safety in the electric vehicle battery pack.

Anode material Specific capacity (mAh/g) Cycle life Rate performance Safety
Natural graphite 340-370 More than 1000 Poor Moderate
Artificial graphite 310-360 More than 1500 Good Good
Mesocarbon microbeads 280-340 More than 1000 Excellent Good
Silicon-carbon composite 380-950 300-500 Moderate Good

I treated the electric vehicle battery pack as a dynamic electrochemical system. The state of charge is one of the most important state variables, and I used the standard definition:

$$SOC=\frac{C_{\mu}}{C_{e}}$$

where \(C_e\) is the rated capacity and \(C_{\mu}\) is the remaining available capacity under a rated discharge current. I also considered terminal voltage, open-circuit voltage, internal resistance, capacity, energy density, power density, and temperature. These parameters are the observable bridge between cell-level degradation and pack-level fault behavior in the electric vehicle battery pack.

I analyzed the failure mechanisms of lithium-ion cells. Capacity fade and resistance rise can be caused by cathode dissolution, electrolyte decomposition, overcharge-induced damage, phase transitions in electrode materials, solid-electrolyte interphase growth, current-collector corrosion, and self-discharge. In an electric vehicle battery pack, these internal changes interact with external mechanical and thermal stresses. The electric vehicle battery pack may experience vibration, humidity variation, irregular charging, and high-rate discharging. Therefore, a robust diagnostic method must not rely on a single measurement or a single operating condition.

I classified the main fault types in the electric vehicle battery pack. Open-circuit faults are easy to detect because the terminal voltage of the affected cell falls to zero or near zero. Consistency faults are related to cell-to-cell variation, but modern manufacturing has reduced their early severity. Virtual connection faults and micro-short-circuit faults are more dangerous because they can cause local overheating and may develop into severe thermal events. For this reason, I concentrated on virtual connection faults and micro-short-circuit faults in the electric vehicle battery pack.

I first studied virtual connection faults. In a series-connected electric vehicle battery pack, cells are joined by connectors and bolts. If a connector becomes loose, the contact area between the connector and the cell terminal changes. Under vibration, the contact resistance fluctuates. I modeled a cell unit with a first-order equivalent circuit model. The terminal voltage can be written as:

$$U_{n}(t)=U_{ocv,n}(t)-I(t)R_{\Omega,n}-U_{p,n}(t)-I(t)R_{c,n}$$

where \(U_{n}(t)\) is the terminal voltage of cell \(n\), \(U_{ocv,n}(t)\) is the open-circuit voltage, \(I(t)\) is the current, \(R_{\Omega,n}\) is the ohmic resistance, \(U_{p,n}(t)\) is the polarization voltage, and \(R_{c,n}\) is the connection resistance. The open-circuit voltage changes smoothly with state of charge. The polarization voltage and internal resistance vary continuously because they are related to electrochemical and material properties. The connection resistance, however, can change abruptly when the connector loosens. This is the physical basis for voltage-based detection of virtual connection faults in the electric vehicle battery pack.

I built a hardware simulation platform to generate fault data. The platform included a vibration table, voltage sensors, a battery charge-discharge tester, and a data acquisition system. I connected several lithium-ion cells in series to form a small electric vehicle battery pack. The cells had a rated capacity of 50 Ah, a charge cutoff voltage of 4.2 V, a discharge cutoff voltage of 3.0 V, and dimensions of 170 mm by 43 mm by 100 mm. The current-loading profile was designed to imitate frequent operating conditions of an electric vehicle battery pack.

Parameter Value
Rated capacity 50 Ah
Charge cutoff voltage 4.2 V
Discharge cutoff voltage 3.0 V
Length × width × height 170 × 43 × 100 mm
Current (A) Duration (s)
0 30
-30 180
-45 60
10 90
-10 90
45 60
30 180

I divided the virtual connection fault evolution into four levels: healthy state, slight fault, moderate fault, and severe fault. In the healthy state, the voltage data were normal. In the slight-fault stage, the voltage deviation was small but detectable. In the moderate-fault stage, the deviation increased. In the severe-fault stage, sparking and strong abnormal voltage fluctuations appeared. I used these levels as labels for supervised learning. This labeling strategy allowed me to evaluate whether a diagnostic model could distinguish not only fault versus no fault but also fault severity in the electric vehicle battery pack.

I then studied micro-short-circuit faults. A micro-short circuit is an early form of internal short circuit. It can be triggered by mechanical abuse, electrical abuse, thermal abuse, metal deposition, dendrite growth, separator damage, or manufacturing defects. In the early stage, the short-circuit resistance is relatively high, the leakage current is small, and the terminal voltage changes slightly. The heat generated by the leakage current may be dissipated, so the temperature rise is not obvious. In the middle stage, the short-circuit resistance decreases, the leakage current increases, and the voltage deviation becomes significant. In the late stage, the separator may collapse, a large-area internal short circuit may form, and thermal runaway can occur. Therefore, early and middle-stage diagnosis is essential for the electric vehicle battery pack.

I used an equivalent-circuit model coupled with a micro-short-circuit resistance. The terminal voltage and current relationship can be expressed as:

$$U_{t}=OCV(SOC)+I_{R}R_{0}+U_{1}$$

$$I_{R}=I-I_{leak}$$

where \(U_t\) is the terminal voltage, \(OCV(SOC)\) is the open-circuit voltage, \(I_R\) is the current through the voltage source, \(R_0\) is the ohmic resistance, \(U_1\) is the polarization voltage, \(I\) is the total current, and \(I_{leak}\) is the leakage current. I built both a software simulation model and a hardware experiment for the electric vehicle battery pack. In the simulation, I connected resistors of different values across individual cells to represent different micro-short-circuit levels. In the hardware experiment, I used a high-precision battery tester and manually connected a parallel resistor to inject the fault.

Simulation parameter Value
Cell chemistry Lithium iron phosphate
Rated capacity 2.3 Ah
Rated voltage 3.3 V
Initial SOC 100%
Internal resistance 0.014 Ω
Initial temperature 25 °C
External parallel resistances 5 Ω, 50 Ω, 100 Ω

I collected voltage data from the electric vehicle battery pack under both normal and faulty conditions. The raw voltage signals contained noise from sensors, electromagnetic interference, vibration, and current switching. This noise can hide early fault signatures. I therefore developed a data-cleaning and filtering strategy before training any classifier. I compared empirical mode decomposition, ensemble empirical mode decomposition, and complete ensemble empirical mode decomposition with adaptive noise. My goal was not simply to obtain the best decomposition, but to find the best trade-off between diagnostic accuracy and diagnostic time for the electric vehicle battery pack.

I used empirical mode decomposition to decompose a voltage signal into intrinsic mode functions and a residual. The sifting process can be summarized as follows. I identified local maxima and minima, constructed upper and lower envelopes, computed the mean envelope, and subtracted it from the signal:

$$h_{1}(t)=x(t)-m_{1}(t)$$

I repeated this process until the resulting component satisfied the intrinsic mode function conditions. The original signal was then reconstructed as:

$$x(t)=\sum_{i=1}^{n} c_{i}(t)+r_{n}(t)$$

where \(c_i(t)\) are intrinsic mode functions and \(r_n(t)\) is the residual. I then used the Pearson correlation coefficient to decide which components should be retained. The coefficient is:

$$r=\frac{\sum_{i=1}^{n}(X_{i}-\bar{X})(Y_{i}-\bar{Y})}{\sqrt{\sum_{i=1}^{n}(X_{i}-\bar{X})^{2}}\sqrt{\sum_{i=1}^{n}(Y_{i}-\bar{Y})^{2}}}$$

where \(X_i\) is an intrinsic mode function and \(Y_i\) is the original voltage signal. Components with very low correlation were treated as noise. I retained the components with higher correlation and reconstructed the cleaned voltage signal. This process improved the visibility of fault-induced voltage deviations in the electric vehicle battery pack.

Component Correlation with signal 1 Correlation with signal 2 Correlation with signal 3 Correlation with signal 4
IMF1 0.046 0.025 0.022 0.035
IMF2 0.044 0.018 0.032 0.033
IMF3 0.024 0.020 0.027 0.042
IMF4 0.031 0.027 0.045 0.044
IMF5 0.0431 0.034 0.051 0.041
IMF6 0.028 0.027 0.075 0.065
IMF7 0.047 0.064 0.082 0.061
IMF8 0.062 0.058 0.089 0.137
IMF9 0.052 -0.198 0.179 0.084
IMF10 0.339 0.371 0.152 0.784
IMF11 0.893 0.883 0.743 0.149
IMF12 0.139 0.103 0.526 —
IMF13 — — -0.094 —

I also implemented ensemble empirical mode decomposition by adding independent white-noise sequences to the original signal and averaging the resulting intrinsic mode functions:

$$x_{i}(t)=x(t)+n_{i}(t)$$

$$c_{j}(t)=\frac{1}{N}\sum_{i=1}^{N} c_{ij}(t)$$

This reduced mode mixing and improved decomposition stability. I then implemented complete ensemble empirical mode decomposition with adaptive noise. In this method, the residual from one stage is treated as the new input, and the decomposition continues until the residual becomes monotonic. Although these improved methods can produce more stable decompositions, they require more computation. For an electric vehicle battery pack, diagnostic delay is not acceptable because a developing fault can generate heat rapidly. I therefore compared the methods using both accuracy and time.

Filtering method Window size Accuracy Time (s)
EMD 20 100% 78.59
EEMD 20 99.63% 104.29
CEEMDAN 20 99.30% 82.77
EMD 30 99.95% 68.40
EEMD 30 99.72% 89.47
CEEMDAN 30 99.25% 89.92
EMD 36 100% 63.71
EEMD 36 99.76% 86.39
CEEMDAN 36 99.91% 105.27
EMD 40 100% 80.34
EEMD 40 100% 107.14
CEEMDAN 40 99.53% 77.78

I selected empirical mode decomposition with Pearson correlation filtering because it gave the best balance between accuracy and time for the electric vehicle battery pack. The improved methods reduced mode mixing, but they consumed more time. In fault diagnosis, a delay of even a few seconds can matter when the electric vehicle battery pack is approaching a dangerous state.

After noise filtering, I introduced an improved voltage-data processing method. In a series-connected electric vehicle battery pack, cell-to-cell inconsistency is unavoidable because of manufacturing tolerances, aging differences, and thermal gradients. The voltage difference between adjacent cells and between adjacent time samples can be very small, which makes it difficult for a convolutional neural network to extract discriminative features. I therefore subtracted the average voltage of all cells at the same time from each cell voltage and multiplied the result by a coefficient:

$$v_{i,j}=v_{i,j}-\bar{v}_{j}\times\alpha$$

$$\bar{v}_{j}=\frac{1}{n}\sum_{i=1}^{n} v_{i,j}$$

where \(v_{i,j}\) is the corrected voltage of cell \(i\) at time \(j\), \(n\) is the number of cells, \(\bar{v}_{j}\) is the average voltage at time \(j\), and \(\alpha\) is a coefficient. I used \(\alpha=1000\) in my experiments. This operation reduced the influence of cell inconsistency, enhanced relative voltage differences, and helped the convolutional neural network learn fault features quickly. I found that this step was essential for the electric vehicle battery pack because raw voltage differences were too small for reliable classification.

I also addressed the small-sample problem. Deep learning models require many training samples, but fault experiments produce limited data. I used a sliding-window method to reconstruct the voltage matrix. If the original data form an \(n \times k\) matrix, where \(n\) is the number of time samples and \(k\) is the number of cells, I extracted sub-matrices of size \(m \times k\) with a sliding step. Each sub-matrix was treated as one sample. This increased the number of samples and preserved local temporal information. I compared different window sizes and found that a window size of 36 gave the best time performance for the two-dimensional convolutional neural network while maintaining very high accuracy.

I then designed a one-dimensional convolutional neural network for fault diagnosis of the electric vehicle battery pack. The network contained convolutional layers, pooling layers, fully connected layers, and dropout layers. The convolution operation can be expressed as:

$$y_{i,j}=f\left(\sum_{m}\sum_{n} w_{m,n}x_{i+m,j+n}+b\right)$$

where \(w\) is the kernel, \(x\) is the input, \(b\) is the bias, and \(f\) is the activation function. I used a \(3 \times 1\) kernel, a stride of 1, and the tanh activation function. The pooling layer reduced the data dimension and improved generalization. I used max pooling for the one-dimensional model and max pooling followed by global average pooling for the two-dimensional model. The Adam optimizer updated the network parameters adaptively:

$$m_{t}=\beta_{1}m_{t-1}+(1-\beta_{1})g_{t}$$

$$v_{t}=\beta_{2}v_{t-1}+(1-\beta_{2})g_{t}^{2}$$

$$\hat{m}_{t}=\frac{m_{t}}{1-\beta_{1}^{t}}$$

$$\hat{v}_{t}=\frac{v_{t}}{1-\beta_{2}^{t}}$$

$$\theta_{t}=\theta_{t-1}-\alpha\frac{\hat{m}_{t}}{\sqrt{\hat{v}_{t}}+\epsilon}$$

I used cross-entropy as the loss function:

$$L=-\frac{1}{N}\sum_{i=1}^{N}\sum_{c=1}^{M} y_{ic}\log p_{ic}$$

where \(N\) is the number of samples, \(M\) is the number of classes, \(y_{ic}\) is the indicator variable, and \(p_{ic}\) is the predicted probability. Dropout was used after the fully connected layers to reduce overfitting. I trained the model until the validation accuracy became stable.

Layer type Configuration Activation
Convolution 1D 3 × 1 kernel, stride 1 tanh
Pooling 1D Width 2, stride 1 —
Convolution 1D 3 × 1 kernel, stride 1 tanh
Pooling 1D Width 2, stride 1 —
Fully connected 128 nodes tanh
Dropout Rate selected during training —
Output 4 classes softmax

I also designed a two-dimensional convolutional neural network. The two-dimensional model treated the voltage matrix as an image-like input. It used \(2 \times 2\) convolution kernels, max pooling with \(2 \times 2\) windows, global average pooling, and two fully connected layers. The first fully connected layer had 128 nodes with tanh activation, and the output layer had 4 nodes with softmax activation. The two-dimensional model captured local spatial patterns across cells and time samples. This was useful for the electric vehicle battery pack because a fault often appears first as a localized deviation in one cell or one connection.

Model Kernel size Pooling Output classes Optimizer
1D CNN 3 × 1 Max pooling 4 Adam
2D CNN 2 × 2 Max pooling and global average pooling 4 Adam

I evaluated the effect of sample reconstruction. When I did not reconstruct the samples, the training accuracy increased, but the test accuracy remained poor and unstable. When I reconstructed the samples with a sliding window, both training and test accuracy increased and stabilized. This confirmed that sample reconstruction was necessary for the electric vehicle battery pack fault data.

I also evaluated the effect of the improved voltage-data processing method. Without processing, the classification accuracy fluctuated around 25%, which was close to random guessing. With processing, the accuracy rose rapidly and reached a stable high value. This showed that the relative voltage difference is a key feature for fault diagnosis in the electric vehicle battery pack.

I compared activation functions. The tanh activation function produced the best stability and highest accuracy. The sigmoid activation function fluctuated and reached only about 90% accuracy. The ReLU activation function reached high accuracy but did not stabilize as quickly as tanh. Based on these results, I used tanh in my final models.

Activation function Accuracy behavior Stability
tanh Highest and fastest convergence Stable
sigmoid Lower accuracy, strong fluctuation Poor
ReLU High accuracy but slower stabilization Moderate

For the one-dimensional convolutional neural network, I obtained a fault diagnosis accuracy of 99.77% after 75 iterations. For the two-dimensional convolutional neural network, I obtained 100% accuracy. The two-dimensional model with a sliding-window size of 36 achieved the best time performance. It reached 100% accuracy in 63.71 s. I compared this with other methods, including a genetic-algorithm-optimized extreme learning machine and a grid-search-optimized support vector machine. My two-dimensional convolutional neural network achieved higher accuracy and shorter diagnosis time. This demonstrated the advantage of my method for the electric vehicle battery pack.

Method Accuracy Time (s)
GA-ELM 97.97% —
GS-SVM 97.50% 167.38
1D CNN 99.77% 100.48
2D CNN 100% 63.71

I then applied the same convolutional neural network framework to micro-short-circuit fault diagnosis in the electric vehicle battery pack. The purpose was both to classify the fault and to test the generalization ability of my model. I used simulation data for normal cells and cells with different micro-short-circuit resistances. I processed the voltage data with the same improved voltage method, reconstructed samples with the sliding-window method, and trained the same network. The qualitative diagnosis reached 95.48% accuracy after 13 iterations, with an error below 5%. This showed that my convolutional neural network structure can be transferred from virtual connection faults to micro-short-circuit faults in the electric vehicle battery pack.

For quantitative diagnosis of micro-short-circuit faults, I used the incremental capacity method. The incremental capacity is defined as the change in capacity divided by the change in voltage:

$$IC=\frac{dQ}{dV}\approx\frac{i_{c}\Delta t}{\Delta V}$$

$$IC=\frac{dQ}{dV}\approx\frac{\Delta Q}{\Delta V}$$

where \(Q\) is the charge capacity, \(V\) is the terminal voltage, \(i_c\) is the charging current, and \(t\) is time. When a micro-short circuit exists, part of the charging current leaks through the short-circuit path. The effective charging current is:

$$I_{effective}=I_{normal}-I_{leak}$$

Because of the leakage current, the micro-short-circuit cell requires more charge to reach the same voltage interval. Therefore, its incremental capacity curve rises faster and has a larger area than that of a normal cell. I used the area difference between the normal and faulty incremental capacity curves to estimate the leakage charge:

$$\Delta Q_{leak,AB}=\Delta Q_{fault,AB}-\Delta Q_{normal,AB}$$

$$\Delta Q_{AB}=\int_{A}^{B}\frac{dQ}{dV}dV$$

I then estimated the average leakage current between two selected voltages:

$$I_{leak,AB}=\frac{\Delta Q_{leak,AB}}{\Delta t_{AB}}$$

The average terminal voltage in the same interval was calculated as:

$$U_{AB}=\frac{1}{n}\sum_{i=1}^{n}U_{i}$$

The number of samples was:

$$n=\frac{\Delta t_{AB}+T_{s}}{T_{s}}$$

Finally, I estimated the micro-short-circuit resistance by Ohm’s law:

$$R_{ISC}=\frac{U_{AB}}{I_{leak,AB}}$$

I applied this method to simulation data for the electric vehicle battery pack. I selected voltage A as 3.3675 V and voltage B as 3.3924 V. The quantity changes and leakage quantities are summarized below.

Battery type Charge quantity change (Ah) Leakage quantity (Ah)
Normal 1.96718 —
MSC with 50 Ω 2.08830 0.12112
MSC with 100 Ω 2.02630 0.05912
Battery type Time in interval (s) Leakage current (A)
Normal — —
MSC with 50 Ω 6537 0.0667
MSC with 100 Ω 6343 0.03355
Battery type n Average voltage (V)
MSC with 50 Ω 6538 3.38179
MSC with 100 Ω 6344 3.38225
Battery type Actual resistance (Ω) Estimated resistance (Ω) Error
MSC with 50 Ω 50 50.72 1.44%
MSC with 100 Ω 100 100.81 0.81%

The simulation results showed that my method estimated the micro-short-circuit resistance with small error. I then validated the method with experimental data. I used a high-precision battery tester and connected a 20 Ω resistor in parallel with a cell to emulate a micro-short circuit. I calculated the incremental capacity curve from the measured voltage and capacity data. The normal cell and the faulty cell both showed characteristic peaks, but the faulty cell curve shifted upward and leftward. I selected the second peak region for quantitative estimation. The charge quantity change was 0.761989 Ah for the normal cell and 0.824923 Ah for the faulty cell. The leakage quantity was 0.062934 Ah. The leakage current was 0.19087 A. The average voltage in the selected interval was 3.7556 V. The estimated micro-short-circuit resistance was 19.68 Ω. The actual parallel resistance was 20 Ω. The error was 1.6%. This confirmed that the incremental capacity method is reliable for quantitative diagnosis of micro-short-circuit faults in the electric vehicle battery pack.

Battery type Charge quantity change (Ah) Leakage quantity (Ah)
Normal 0.761989 —
MSC experimental 0.824923 0.062934
Item Value
Leakage current 0.19087 A
Average voltage 3.7556 V
Actual parallel resistance 20 Ω
Estimated MS resistance 19.68 Ω
Error 1.6%

I also considered the broader implications for the electric vehicle battery pack. Virtual connection faults and micro-short-circuit faults have different physical origins, but both can be detected through voltage anomalies. Virtual connection faults produce fluctuating contact resistance and abrupt voltage deviations under vibration. Micro-short-circuit faults produce gradual leakage current and incremental capacity curve changes. My data-driven method using convolutional neural networks is effective for classification and severity grading. My incremental capacity method is effective for quantitative estimation of micro-short-circuit resistance. Together, these methods provide complementary tools for monitoring the electric vehicle battery pack.

I found several practical lessons. First, noise filtering should not be selected only by decomposition quality. The improved decomposition methods can reduce mode mixing, but they may increase computation time. For an electric vehicle battery pack, fast diagnosis is critical. Second, voltage preprocessing is essential. Cell inconsistency can hide early faults. Subtracting the pack average and amplifying the residual improves the separability of fault features. Third, sample reconstruction with a sliding window is necessary for deep learning when fault data are limited. Fourth, the two-dimensional convolutional neural network can capture spatial and temporal patterns in the voltage matrix and can achieve excellent accuracy and speed. Fifth, incremental capacity analysis provides a physically interpretable way to quantify micro-short-circuit severity in the electric vehicle battery pack.

I also recognize the limitations of my work. I assumed that each faulty cell had one dominant fault type. In reality, an electric vehicle battery pack may experience coupled faults. A cell may have a micro-short circuit and increased internal resistance at the same time. A connector may be loose while the cell is also aging. Future work should consider multi-fault coupling and fault prioritization. I also did not fully model the electrochemical and thermal processes inside the cell. A stronger combination of electrochemical modeling, thermal modeling, and data-driven diagnosis would improve the interpretability and reliability of the electric vehicle battery pack diagnosis.

Another limitation is aging. Cells in an electric vehicle battery pack age at different rates. Aging changes capacity, internal resistance, and voltage response. An aging cell may produce voltage deviations that resemble a fault. To reduce false alarms, future methods should include aging scaling factors or state-of-health compensation. The diagnostic model should distinguish reversible operating variation, normal aging, and true faults in the electric vehicle battery pack.

Despite these limitations, my results show that the proposed framework can diagnose virtual connection faults and micro-short-circuit faults in the electric vehicle battery pack with high accuracy and short response time. The main contributions of my work can be summarized in the following table.

Contribution Method Result
Noise filtering EMD with Pearson correlation Improved signal quality and reduced diagnosis time
Voltage preprocessing Pack-average subtraction and coefficient amplification Reduced inconsistency and enhanced fault features
Sample expansion Sliding-window reconstruction Increased sample number and improved training stability
Virtual connection diagnosis 1D CNN and 2D CNN 99.77% and 100% accuracy
Micro-short-circuit qualitative diagnosis CNN with same framework 95.48% accuracy
Micro-short-circuit quantitative diagnosis Incremental capacity method Resistance error below 2%

I believe that the electric vehicle battery pack will continue to require advanced diagnostic algorithms as electric vehicles become more common. The battery management system must not only estimate state of charge and state of health but also detect early faults, isolate abnormal cells, and protect the electric vehicle battery pack from thermal runaway. My work shows that data-driven methods can be accurate and fast when they are combined with appropriate signal processing and physical interpretation.

For future work, I plan to integrate electrochemical models with data-driven classifiers. I will study multi-fault coupling and develop a hierarchical diagnosis strategy. I will also consider aging compensation and thermal effects. I will test the methods on larger electric vehicle battery pack configurations and under more realistic driving cycles. I will explore online implementation on embedded hardware so that the electric vehicle battery pack can be monitored in real time. I will also investigate how to transfer models between different cell chemistries and different pack designs.

In summary, I designed a complete diagnostic framework for the electric vehicle battery pack. I used empirical mode decomposition and Pearson correlation to clean voltage signals. I proposed an improved voltage-data processing method to reduce cell inconsistency and amplify fault features. I used a sliding-window method to reconstruct samples for deep learning. I built one-dimensional and two-dimensional convolutional neural networks for virtual connection fault diagnosis. I achieved 99.77% accuracy with the one-dimensional model and 100% accuracy with the two-dimensional model. I applied the same convolutional neural network framework to micro-short-circuit fault diagnosis and achieved 95.48% qualitative accuracy. I used the incremental capacity method to quantitatively estimate micro-short-circuit resistance, with errors below 2% in both simulation and experiment. These results demonstrate that the proposed methods are effective, accurate, and timely for fault diagnosis of the electric vehicle battery pack.

Scroll to Top